Minimum Clearance To Combustible Enclosures - Napoleon GD19N Installation And Operating Instructions Manual

Vented natural & propane gas fireplaces
Table of Contents

Advertisement

5.2

MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

* See "VENTING" section
* See "VENTING" section
The appliance requires a minimum enclosure height of 53 1/8" for a top vent, and 39 1/8" for a rear vent. For
temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
** When terminating vertically on a top vented appliance, the height clearance can be reduced to 39 1/8".
COMBUSTIBLE
6"
39 1 /8"
33 1 /8"
COMBUSTIBLE
20"
1"
53 1 /8"
**
33 1 /8"
NON-COMBUSTIBLE
BRICK
2"
1"
MINIMUM
PLUS RISE *
1"
NON-COMBUSTIBLE
BRICK
2"
6"
1"
PLUS RISE *
1"
0" IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AND
STONE.
26 3 /8"
0" IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK AND
STONE.
43 1 /8"
MINIMUM
35
W415-1004 / B / 08.10.12