Electrical Installation Instructions - Jackson JP-24BPNSU Technical Manual

Jackson hot water sanitizing undercounter dishmachine technical manual
Table of Contents

Advertisement

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

ELECTRICAL INSTALLATION INSTRUCTIONS

ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the
National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.
The dishmachine data plate is located on the right side and to the front of the machine. Refer to the data plate for machine
operating requirements, machine voltage, total amperage load and serial number.
Terminal Block
Ground Lug
To install the incoming power lines, remove the kick panel. This will require tak-
ing a phillips head screwdriver and removing the four(4) screws on the front
cover of the kick plate. Install 3/4" conduit into the pre-punched holes in the
back of the control box. Route power wires and connect to power block and
grounding lug. Install the service wires (L1, L2 and L3) to the appropriate ter-
minals as they are marked on the terminal block. Install the grounding wire into
the lug provided. Tighten the connections and perform the "pull test". The tight-
ened wires should remain in place after giving the wires a moderate pull to see
if they will come loose.
It is recommended that "DE-OX" or another similar anti-oxidation agent be
used on all power connections.
VOLTAGE CHECK: Ensure that the power switch is in the
Control Box Electrical Connection
OFF position and apply power to the dishmachine. Check
the incoming power at the terminal block and ensure it cor-
responds to the voltage listed on the data plate. If not, con-
tact a qualified service agency to examine the problem. Do
not run the dishmachine if the voltage is too high or too
low. Shut off the service breaker and mark it as being for
the dishmachine. Advise all proper personnel of any prob-
Brass Plug
lems and of the location of the service breaker. Replace
the control box cover and tighten down the screws.
CHEMICAL CONNECTIONS: All chemical hookup loca-
Rinse Aid Fitting
tions are located on the back of the dishmachine. Please
refer to the drawing at the right for the correct connection
point.
This equipment is not recommend for use with deion-
ized water or other aggressive fluids. Use of deion-
Detergent Fitting
ized water or other aggressive fluids will result in cor-
rosion and failure of materials and components. Use
of deionized water or other aggressive fluids will void
the manufacturer's warranty.
Back of Unit Showing Chemical Connection Points
JP-24BPNSU Technical Manual
7610-002-38-50 Rev. D (11/11/2005)
6