Sliding imperial fitting onto new thermostat.
6. Slide the new imperial brass fitting from your kit onto the
new thermostat.
Putting the new thermostat in the well (Tempstar).
7. Insert the new thermostat/brass fitting combination into the
well and tighten down the brass fitting by hand.
Tightening the brass fitting (Tempstar).
8. Use the 7/16" combination wrench to tighten down the
brass fitting, while also positioning the new thermostat so that
it does not hang over the heater.
SECTION 5: SERVICE PROCEDURES
RINSE REGULATING THERMOSTAT REPLACEMENT
JP-24 Technical Manual 7610-002-49-79 Rev. D
Issued: 03-06-2006 Revised: N/A
9. Note: regardless of the unit this is being done to, the con-
cept is to ensure that the thermostat cannot come into contact
with the heater leads or interfere with the placement of any
covers.
What the installed thermostat should look like (Tempstar).
What the installed thermostat should look like (JP-24B).
Removing the thermostat screws.
10. Use the phillipshead screwdriver to remove the attach-
ment screws on the thermostat for the NORMALLY CLOSED
and COMMON points.