Technical Data - Fujitsu Primergy RX200 S4 Operating Manual

Intel-based server
Hide thumbs Also See for Primergy RX200 S4:
Table of Contents

Advertisement

Preface
1.5

Technical data

Electrical data (hot-plug power supply unit)
Rated voltage range
Frequency
Rated current with basic configuration
Max. rated current
Effective power
Apparent power
Heat dissipation
Main power fuse
Protection class
Compliance with regulations and standards
Product safety and
ergonomics
Electromagnetic
compatibility
Interference emissions EN 55022 class A
Harmonic current EN 61000-3-2
Flicker
Interference immunity
CE marking
to EU directives
RX200 S4
100 V - 127 V or 200 V - 240 V
50 Hz - 60 Hz
100 V - 240 V / 5 A - 2.5 A
100 V - 240 V / 8 A - 4 A
530 W
555 VA
1900 kJ/h (1810 btu/h)
16 A
I
IEC 60950-1 / EN 60950-1, UL/CSA 60950-1,
CNS 14336 / GB 4943 / EN 50371
FCC class A
CNS 13438 class A; VCCI class A
AS/NZS CISPR 22 class A / GB 9254 class A
GB 17625
EN 61000-3-3
EN 55024, EN 300386
Low Voltage Directive 2006/95/EC
(Product Safety)
Electromagnetic Compatibility 2004/108/EC