Cds - Henny Penny 61 Operator's Manual

Smart cooking system
Table of Contents

Advertisement

Functions – CalcDiagnosis System
05.19.04
6
05.20.04
7
Set the desired date using the central dial and
press the central dial to confirm.
The start time is activated.
After 10 seconds the display begins alternating
between real time and the start time. All other cabi-
net lighting is switched off.
06:00
start time
02:00
(real Time)
Note:
Or you can put steps 2-7 before step 1.
De-activating start time
Select function
start time
start time
Caution!
• Do not keep food in an un-cooled or un-
heated condition for a prolonged period!
®

CDS

The CalcDiagnosis System
steam generator based on the amount of use.
The CalcDiagnosis System
limescale build-up in the steam generator and dis-
plays the level graphically as a red bar.
1
CDS
Limescale level displayed:
Note:
When 8 red bars are indicated, the display shows:
CalcCheck
for 10 seconds.
Steam generator should be delimed within the next
3-4 weeks.
When 9 red bars are indicated, display shows:
CalcCheck
for 2 minutes.
The steam generator MUST be delimed within 2
weeks at the most!
- 51 -
®
rinses and drains the
®
also monitors the