Functions – HACCP logging
HACCP process data is logged continuously and
stored for up to one week. Data can be down-
loaded at anytime via the unit interface.
You will need a PC or notebook computer and
CombiLink
®
software. Detailed instructions for set-
ting up the interface are found in the CombiLink
users guide.
To output stored process data:
1
HACCP
2
Continuous process data output is interrupted.
07.18.03
3
4
Start time (date/time of day)
07.25.03
5
6
Finish time (date/time of day)
Download
7
®
09:15
09:15
- 47 -
The following data is logged:
Data output every 60 sec (in ASCCII format)
• Batch no.
• Time of day
• Cooking program no. or name
• Cooking cabinet temperature
• Core temperature
• Door open /door closed
• Change of cooking mode
• CleanJet
®
‚ cleaning
• 1/2 energy
• Demand-related energy supply