Method B.1 (Quick Term) For Shield Termination; Shielded Cable Preparations – (Quick Term) - Garmin GDU 37X Installation Manual

Hide thumbs Also See for GDU 37X:
Table of Contents

Advertisement

Secondary Method:
Solder a Flat Braid (item 4) to the folded back shield on the prepared cable assembly (item 2). Ensure
a solid electrical connection through the use of acceptable soldering practices. Use care to avoid
applying excessive heat that burns through the insulation of the center conductors and shorts the shield
to the signal wire. Slide a minimum of 0.75 inches of Teflon heat shrinkable tubing (item 3) onto the
prepared wire assembly and shrink using a heat gun. The chosen size of heat shrinkage tubing must
accommodate both the number of conductors present in the cable as well as the Flat Braid (item 4) to
be attached.
Teflon Heat Shrinkable Tubing:
Reference the following MIL-Spec for general Teflon heat shrinkable tubing (M23053/5-X-Y)
Figure B-5 Method B.1 (Quick Term) for Shield Termination
Table B-4 Shielded Cable Preparations – (Quick Term)
Number of Pins
Backshell Size
1
2
3
4
5
GDU 37X Installation Manual
190-01054-01
Quick Term
Std/HD
Min (inches)
9/15
1.25
15/26
1.5
25/44
1.5
37/62
1.5
50/78
1.5
Quick Term
Quick Term
Max (inches)
Float (inches)
2.25
2.5
2.5
2.5
2.5
1.75
2.0
2.0
2.0
2.0
Page B-9
Revision C