UX-40DE
FO-50DE
3. 12. Country select
This mode is used to set line connecting parameters which correspond
to each destination.
When the country select mode is selected, and then the START key is
pressed, the destination (country name) currently set will be displayed.
By pressing the # or
key, selectable destinations (country names) are
displayed. When the destination (country name) you want to choose is
displayed, press the START key. Each parameter will be stored in RAM.
Destinations (Country names) you can select are as follows:
COUNTRY NAME
AUSTRIA
(AT)
GERMANY
(DE)
FRANCE
(F)
Note: Be sure to execute the memory clear mode whenever you
change the country select setting. The default settings of the
soft switches vary according to the destinations. Therefore, if
you do not execute the memory clear after changing the coun-
try select setting, some functions may not work.
Do not set a country select setting which is different from that
of the destination of the machine. Some functions will not work
because the function and the PWB specifications are different.
4. How to make soft switch setting
To enter the soft switch mode, press the following key entries in se-
quence.
Press FUNCTION
DATA No.
S F T SW-A1 = 0 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A2 = 0 0 0 0 0 0 0 0
S F T SW-M2 = 0 0 0 0 0 0 0 0
9
8
7
1 2 3 4 5 6 7 8
The soft switch mode is terminated.
2 – 4
START
START
Press FUNCTION key.
Press
key.
Press
key.
Bit1 - 8 are set.
Press
key during setting.
START
Soft SW-A2 - SW-K1 are set.
To finish the settings halfway between
SW-A1 and SW-K1, press the STOP
key. In this case, the setting being done
to the SW No. on display will be nullified
while settings done to the preceding
SW Nos. remain in effect.
When the COPY key is pressed, the
contents of soft switches are printed.