FO-50DE

[2] Diagnostics and service soft switch

1. Operating procedure
(1) Entering the diagnostic mode
Press FUNC → 9 →
→ 8 → # → 7 , and the following display will appear.
ROM Ver. FZP0
After 2 sec: DIAG MODE
FZP0
Then press the START key and country name selected by country select will appear. Select the desired item with the
with the direct key. Enter the mode with the START key.
(Diag•specifications)
FUNC
9
8
7
If the diag mode cannot be set, repeat the diag mode operation, per-
forming the following operation.
After the power is turned on and "WAIT A MOMENT" is indicated, press
the STOP key.
2. Diagnostic items
ITEM
DIRECT
No.
key
1
2
A
3
4
5
B
6
C
7
8
9
D
10
E
11
12
FZP0
DIAG MODE
Soft switch mode
ROM & RAM check
Aging mode
Panel check mode
Check pattern
Signal send mode
STOP
KEY
+
"Power ON"
Memory clear
(Work + Backup)
Contents
SOFT SWITCH MODE
Soft switches are displayed and changed. List can be output.
ROM & RAM CHECK
ROM is sum-checked, and RAM is matched. Result list is output.
AGING MODE
10 sheets of check patterns are output every 5 minutes per sheet.
PANEL CKECK MODE
Panel keys are tested. Result list is output.
CHECK PATTERN
2 sheets of check patterns are output.
SIGNAL SEND MODE
Various signals of FAX communication are output.
MEMORY CLEAR
Back-up memory is cleared, and is set at delivery.
SHADING MODE
Shading compensation is performed in this mode.
ALL BLACK PRINT
To check the print head, whole dots are printed over the interval of 2 m.
AUTO FEEDER MODE
Insertion and discharge of document are tested.
MESSAGE PRINT
The display message of each language is printed out together with the English equivalent.
COUNTRY SELECT
The software parameter that it agreed in each country name is set up.
START
START
START
A
START
START
START
B
START
C
START
KEY
In relation with the process response (request from Production
Engineering) "WAIT A MOMENT" clock indication may appear depending
on STOP key timing. If the STOP key is held down, "MEMORY CLEAR?"
appears.
2 – 2
key or the # key or select
START
START
E
START
D
START
START
START
Function
Country select
Massage print
Auto feeder mode
All black mode
Shading mode
Memory clear

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fo-50Ux-40deFo-50de

Table of Contents