Panasonic PT-CW230E Service Manual page 33

Dlp based projector
Hide thumbs Also See for PT-CW230E:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
4 Fan 3 Min Adjust (DAC)
5 Fan 3 Max Adjust (DAC)
6 Fan 4 Min Adjust (DAC)
7 Fan 4 Max Adjust (DAC)
8 Fan 5 Min Adjust (DAC)
9 Fan 5 Max Adjust (DAC)
10 Fan 6 Min Adjust (DAC)
11 Fan 6 Max Adjust (DAC)
Group
Fan Option
252
1 Safety Switch
2 Fan Manual Switch
3 Fan1 Manual Voltage
4 Fan2 Manual Voltage
5 Fan3 Manual Voltage
6 Fan4 Manual Voltage
7 Fan5 Manual Voltage
8 Fan6 Manual Voltage
9 All Fan MaxMin Control
Group
FAN Error Setting
253
0 Temp A Warning (Normal)
1 Temp B Warning (Normal)
2 Temp C Warning (Normal)
3 Temp B-A Waninig (Normal)
4 Temp C-A Warning (Normal)
5 Temp A Warning (Eco)
6 Temp B Warning (Eco)
7 Temp C Warning (Eco)
8 Temp B-A Warninig (Eco)
9 Temp C-A Warning (Eco)
10 Temp A Warning Offset (Temp)
11 Temp B Warning Offset (Temp)
12 Temp C Warning Offset (Temp)
13 Temp B-A Warning Offset (Temp)
14 Temp C-A Warning Offset (Temp)
15 Temp A Warning Offset (Time)
16 Temp B Warning Offset (Time)
17 Temp C Warning Offset (Time)
18 Temp B-A Warning Offset (Time)
19 Temp C-A Warning Offset (Time)
Function
For Safety Application purpose
0: Auto, 1: Manual
Fan1 Voltage (x0.1V)
Fan2 Voltage (x0.1V)
Fan3 Voltage (x0.1V)
Fan4 Voltage (x0.1V)
Fan5 Voltage (x0.1V)
Fan6 Voltage (x0.1V)
Forced Fan Mode
0: Normal, 1: Normal-Min, 2: Normal-Max,
3: Eco-Min, 4: Eco Mox
Temperature A to judge the Temp. Failure
Outside at Normal
Temperature B to judge the Temp. Failure
DMD at Normal
Temperature C to judge the Temp. Failure
Lamp at Normal
Temperature B-A to judge the Temp. Failure
Filter Clogged at Normal
Temperature C-A to judge the Temp. Failure
Filter Clogged at Normal
Temperature A to judge the Temp. Failure
Outside at Eco
Temperature B to judge the Temp. Failure
DMD at Eco
Temperature C to judge the Temp. Failure
Lamp at Eco
Temperature B-A to judge the Temp. Failure
Filter Clogged at Eco
Temperature C-A to judge the Temp. Failure
Filter Clogged at Eco
L1
Initial
31
234
27
237
28
239
28
238
0
0
100
100
100
100
100
100
0
L1
L2
L3
L4
Normal
Ceiling
Bottom
Up
48
48
48
48
68
67
67
68
68
67
68
68
100
100
100
100
100
100
100
100
50
49
49
49
71
71
70
70
73
72
73
73
100
100
100
100
100
100
100
100
12
11
13
11
13
30
15
15
15
15
L3
L2
L4
-33-
Range
Note
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 4
0 - 1
0 - 145
0 - 145
0 - 145
0 - 145
0 - 145
0 - 145
0 - 4
30 - 100
30-100
30-100
0-100
0-100
30 - 100
30 - 100
30 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 40
0 - 40
0 - 40
0 - 40
0 - 40