Induction and electric cooktops

Advertisement

Cooktop Specifications
Installation Requirements
IMPORTANT NOTE: Installation of the induction or electric
cooktop must meet location requirements shown in the
installation illustration for your specific model on the
following pages. All dimensions listed are minimum
requirements for safe operation.
Wolf induction and electric cooktops are intended for
indoor use. For ease of installation, Wolf recommends
using 33"
wide cabinets with 30"
(838)
39"
cabinets with 36"
(991)
designed to fit a standard 24"
a 25"
deep countertop. Before making the countertop
(635)
cut-out, verify that the cooktop will clear the side walls of
the base cabinet.
A minimum height clearance of 6
the top of the countertop to any combustible surface
directly below the cooktop. For induction cooktops, if a
shelf is installed below the unit, a 1"
the shelf is necessary to allow for proper ventilation.
Clearance is required for the conduit located at the right
rear of induction and electric cooktops. Refer to the illus-
tration below for dimensions.
1
1
/
"
4
(32)
2"
2"
(51)
(51)
Conduit dimensions.
cooktops and
(762)
cooktops. They are
(914)
deep base cabinet with
(610)
1
/
"
is required from
(159)
4
gap at the rear of
(25)
Failure to locate the cooktop without proper clearances
will result in a fire hazard.
It is recommended that you use a Wolf cooktop ventilation
hood, pro hood or hood liner with induction and electric
cooktops. Framed cooktops can accommodate a Wolf
downdraft ventilation system. Refer to the Wolf design
guide.