Tcc-Link Central Control Remote Controller (Tcb-Sc642Tle) - Toshiba RAV-SM562KRT-E Service Manual

Hi wall type (indoor unit)
Hide thumbs Also See for RAV-SM562KRT-E:
Table of Contents

Advertisement

TCC-LINK Central Control Remote Controller (TCB-SC642TLE)

(1) Checking
When an error occurs in the air conditioner, a
check code and an indoor unit number appear on
the LCD of remote controller.
Check code is displayed only during operation.
If indication disappears, check errors following
"Checking Error Log" below.
(2) Checking Error Log
When an error occurs in the air conditioner, error log can be checked following the steps below. Up to 4
errors are memorized.
Error log can be checked in both operation ON and OFF states.
A Press [SET] and [TEST] at the same time for 4 seconds or more.
B Indication of "SERVICE CHECK" and UNIT No. "01" appear.
C When selecting a group number (blinking), a unit number and the latest error log, if any, are displayed
alternately.
* Temperature setting is disabled at this time.
Indication of unit number
UNIT No.
R.C.
D To check other errors, choose a code (01 to 04) with TEMP. ∆/∇ buttons.
E To check error log of another group, choose a group number with / buttons.
Do not press [CL] as this button clears entire error log of the selected group.
F Press [TEST] to finish the service check.
Alternate blinking
No.
Indication of unit number
UNIT No.
R.C.
No.
Indication of alarm
CHECK
36
Indication of alarm
CHECK
Alternate blinking

Hide quick links: