Panasonic S-26PU1U6 Operating Instructions Manual
Panasonic S-26PU1U6 Operating Instructions Manual

Panasonic S-26PU1U6 Operating Instructions Manual

Split system air conditioner
Hide thumbs Also See for S-26PU1U6:

Advertisement

* Shows U1 type
Model No.
Indoor Units
Type
Indoor Unit Type
U1
4-Way Cassette
S-26PU1U6
K1
Wall Mounted
S-26PK1U6
T1
Ceiling
S-26PT1U6
Low Silhouette
F1
S-26PF1U6
Ducted
Outdoor Units
Type Outdoor Unit Type
U-26PE1U6
U
Single
U-26PS1U6
Remote Controllers
Timer Remote Controller (wired)
Wireless Remote Controller (for F1 type)
Wireless Remote Controller (for U1 type)
Wireless Remote Controller (for K1 type)
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
85464609163012
26
36
S-36PU1U6
S-36PT1U6
S-36PF1U6
26
36
U-36PE1U6
U-36PS1U6
CZ-RTC2
Timer Remote Controller comes with Instructions Manual.
CZ-RWSC1U
CZ-RWSU1U
CZ-RWSK1U

Operating Instructions

Split System Air Conditioner
42
S-42PU1U6
with Wired Remote Controller: CZ-RTC2
with Wireless Remote Controller: CZ-RWSK1U
S-42PT1U6
with Wired Remote Controller: CZ-RTC2
with Wired Remote Controller: CZ-RTC2
42
U-42PE1U6
Cooling/Heating
U-42PS1U6
Cooling
This air conditioner uses the refrigerant R410A.
Remarks
Remarks
CV6233186917

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-26PU1U6

  • Page 1: Operating Instructions

    Operating Instructions Split System Air Conditioner * Shows U1 type Model No. Indoor Units Type Indoor Unit Type Remarks 4-Way Cassette S-26PU1U6 S-36PU1U6 S-42PU1U6 with Wired Remote Controller: CZ-RTC2 Wall Mounted S-26PK1U6 with Wireless Remote Controller: CZ-RWSK1U Ceiling S-26PT1U6 S-36PT1U6...
  • Page 2: Table Of Contents

    163011_SingleSplit_EN_1.fm Page 2 Thursday, September 15, 2011 9:00 AM CONTENTS Page PRODUCT INFORMATION ......................2 SAFETY PRECAUTIONS......................2 INSTALLATION LOCATION......................3 ELECTRICAL REQUIREMENTS ....................3 SAFETY INSTRUCTIONS......................3 OPERATION CONDITION ......................4 NAMES OF PARTS ........................5 ADJUSTING AIRFLOW DIRECTION ....................6 CARE AND CLEANING ........................8 SPECIAL REMARKS ........................10 TROUBLESHOOTING (BEFORE CALLING FOR SERVICE).............11 TIPS FOR ENERGY SAVING .....................11 WIRELESS REMOTE CONTROLLER ..................12...
  • Page 3: Installation Location

    163011_SingleSplit_EN_1.fm Page 3 Thursday, September 15, 2011 9:00 AM INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
  • Page 4: Operation Condition

    163012_SingleSplit_EN_1.fm Page 4 Tuesday, November 1, 2011 9:58 AM • For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. • Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
  • Page 5: Names Of Parts

    163011_SingleSplit_EN_1.fm Page 5 Thursday, September 15, 2011 9:00 AM NAMES OF PARTS INDOOR UNIT 4-Way Cassette Wall Mounted U1 type (4-WAY) K1 type Air intake Celling panel (optional) Air outlet Air intake Air outlet Ceiling Low Silhouette Ducted T1 type F1 type Ceiling Air outlet...
  • Page 6: Adjusting Airflow Direction

    163011_SingleSplit_EN_1.fm Page 6 Thursday, September 15, 2011 9:00 AM ADJUSTING AIRFLOW DIRECTION 4-Way Cassette (U1) This air conditioner is equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller.
  • Page 7 163011_SingleSplit_EN_1.fm Page 7 Thursday, September 15, 2011 9:00 AM ADJUSTING AIRFLOW DIRECTION (CONTINUED) Wall mounted (K1) A. Vertical directions (automatic) Confirm that the remote controller has been turned on. Press the FLAP button to start the flap moving up and down. If you want to stop the flap movement and to direct the air in the desired Indoor unit direction, press the FLAP button again.
  • Page 8: Care And Cleaning

    163011_SingleSplit_EN_1.fm Page 8 Thursday, September 15, 2011 9:00 AM CARE AND CLEANING 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard.
  • Page 9 163011_SingleSplit_EN_1.fm Page 9 Thursday, September 15, 2011 9:00 AM CARE AND CLEANING (CONTINUED) How to remove the filter 4. Remove the air filter attached to the air intake grille. (continued) Latch Safety chain Air intake grille Air filter Bolt screw How to remove the filter (continued) Ceiling type (T1): 1.
  • Page 10: Special Remarks

    163011_SingleSplit_EN_1.fm Page 10 Thursday, September 15, 2011 9:00 AM SPECIAL REMARKS Heating Operation Heating performance • Because this appliance heats a room by utilizing the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this heat pump, use another heating appliance in conjunction with this unit.
  • Page 11: Troubleshooting (Before Calling For Service)

    163011_SingleSplit_EN_1.fm Page 11 Thursday, September 15, 2011 9:00 AM TROUBLESHOOTING (BEFORE CALLING FOR SERVICE) If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. Trouble Possible Cause Remedy...
  • Page 12: Wireless Remote Controller

    163011_SingleSplit_EN_2Cover.fm Page 12 Thursday, September 15, 2011 8:59 AM WIRELESS REMOTE CONTROLLER Model No. Remote Controllers Wireless Remote Controller (for F1 type) CZ-RWSC1U Wireless Remote Controller (for U1 type) CZ-RWSU1U Wireless Remote Controller (for K1 type) CZ-RWSK1U...
  • Page 13 163011_SingleSplit_EN_2.fm Page 13 Tuesday, September 27, 2011 4:23 PM UNIT DISPLAY AND OPERATION CONTROLLER FOR K1, U1, AND T1 TYPES Remote control receiver OPERATION TIMER lamp STANDBY lamp lamp Remote control receiver OPERATION lamp TIMER lamp STAND BY lamp OPERATION lamp This lamp lights when the appliance is turned on.
  • Page 14 163011_SingleSplit_EN_2.fm Page 14 Thursday, September 15, 2011 9:03 AM UNIT DISPLAY AND OPERATION CONTROLLER FOR K1, U1, AND T1 TYPES (CONTINUED) To access operation Press on the two latches of the air intake grille with your thumb in the direction of the arrow to open controller: the grille.
  • Page 15 163011_SingleSplit_EN_2.fm Page 15 Thursday, September 15, 2011 9:03 AM OPERATION CONTROLLER WITH RECEIVER (SEPARATED FROM INDOOR UNIT) FOR F1 TYPE A: Operation controller B: Remote control receiver C: ON/OFF operation button D: SWEEP button E: SERVICING switches F: Switch G: ADDRESS switch H: OPERATION lamp I: TIMER lamp J: STANDBY lamp...
  • Page 16 163011_SingleSplit_EN_2.fm Page 16 Thursday, September 15, 2011 9:03 AM USING WIRELESS REMOTE CONTROLLER How to Install Batteries 1. Press and slide the cover on the back of the wireless remote controller in the direction of the arrow. 2. Install two AAA alkaline batteries (LR03). Make sure the batteries point in the direction marked in the battery compartment.
  • Page 17 163011_SingleSplit_EN_2.fm Page 17 Thursday, September 15, 2011 9:03 AM USING WIRELESS REMOTE CONTROLLER (CONTINUED) How to Use Wireless When using the wireless remote controller, always point the unit’s transmitter head directly at Remote Controller the air conditioner’s receiver. Air conditioner (Transmitter head) Remote control receiver Wireless remote controller...
  • Page 18: Remote Controller

    163011_SingleSplit_EN_2.fm Page 18 Thursday, September 15, 2011 9:03 AM REMOTE CONTROLLER 15. Sensor button Use this when switching to detect the 1. Operation Display Displays the operation status. temperature at the remote controller. (The figure shows all the statuses.) At shipping the default setting is set •...
  • Page 19 163011_SingleSplit_EN_2.fm Page 19 Thursday, September 15, 2011 9:03 AM HOW TO SET ADDRESS ( Setting addresses of indoor units for remote controller Setting Remote Control Addresses 1. If you press at the same time, “SET” will blink. 2. While holding down, every time you press , it cycles from ALL 3…...
  • Page 20 163011_SingleSplit_EN_2.fm Page 20 Thursday, September 15, 2011 9:03 AM OPERATION Setting Current Time After changing the batteries and pressing reset, be sure to reset the current time. (When reset is pressed, the current time reverts to [ 1. Press for two seconds or more. Once the clock displays starts blinking, the clock can be set.
  • Page 21 163011_SingleSplit_EN_2.fm Page 21 Thursday, September 15, 2011 9:03 AM <Auto Operation> If all the indoor units are identical in a cooling system and are under control as one group, it heats or cools automatically via the differences between the set temperature and the room temperature.
  • Page 22 163011_SingleSplit_EN_2.fm Page 22 Thursday, September 15, 2011 9:03 AM Combining ON and OFF Timers • Setting the ON and OFF timers, respectively. Checking the timer setting • If you press either for the or the , the scheduled time is displayed for four seconds. •...
  • Page 23 163011_SingleSplit_EN_2.fm Page 23 Thursday, September 15, 2011 9:03 AM Adjusting Wind Direction • Never try to manually move the flap (up-down wind direction plate) that is operated by the remote controller. • When the unit stops, the flap (up-down wind direction plate) automatically faces downwards. •...
  • Page 24 163011_SingleSplit_EN_2.fm Page 24 Thursday, September 15, 2011 9:03 AM OPERATION WITHOUT WIRELESS REMOTE CONTROLLER STEP 2 STEP 1,3 If you have lost the wireless remote controller or if it is not working properly, follow the steps below: STEP 1 To start the air conditioner Press the ON/OFF operation button (automatically setting cooling or heating operation).
  • Page 25: Specifications

    30-23 / 32 (780) 37 (940) 13-3 / 8 (340) 128 (58) Single-phase, 24,800 29,800 208-230 V, 60 Hz Indoor S-26PU1U6 38/35/31 13-5 / 16 (338) 33-55 / 64 (860) 33-55 / 64 (860) 60 (27) Outdoor U-36PE1U6 30-23 / 32 (780)
  • Page 26 30-23 / 32 (780) 37 (940) 13-3 / 8 (340) 128 (58)) Single-phase, 24,000 28,600 208-230 V, 60 Hz Indoor S-26PU1U6 34/30/27 12-7 / 32 (310) 39-3 / 8 (1,000) 24-13 / 16 (630) 71 (32) Outdoor U-36PE1U6 30-23 / 32 (780)
  • Page 27 163011_SingleSplit_EN_2.fm Page 27 Thursday, September 15, 2011 9:03 AM...
  • Page 28 BE0711-21111 Printed in Japan...

Table of Contents