Pin Aux Output Harness - Code Alarm ca 1151 Installation Manual

Professional series security and keyless entry
Hide thumbs Also See for ca 1151:
Table of Contents

Advertisement

3 Pin AUX Output Harness

1
VIOLET/BLACK
This wire provides a ( - ) 300mA output capable of driving relays. For Control of
optional accessories (i.e. Power Window/Sunroof, etc.).
To activate refer to the transmitter button configuration chart. Please refer to the
selectable options for timing.
2
GREEN/BLACK
This wire will supply a ( - ) 300mA pulse both upon disarming the system and
when the trunk release feature is activated. Locate the factory perimeter alarm
disarm wire from the key cylinder inside the drivers door.
Verification: This wire registers ground if the key is turned to the unlock
position in the driver's door cylinder.
Connect the GREEN/BLACK wire to the factory alarm disarm wire.
3
BROWN/BLACK
Locate the vehicle's horn wire.
Verification: This wire will register at positive voltage and register
ground when the horn switch is pressed.
Connect the BROWN/BLACK wire to the vehicle's horn wire. This is a low current
output, 300mA.
8
AUX 1 OUTPUT ( - )
FACTORY DISARM ( - )
HORN OUTPUT ( - )
ca1151 rev B. 2011 Audiovox Electronics Corporation. All rights reserved.