Fujitsu SPARC Enterprise M8000 Product Notes page 40

For xcp version 1041
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

Specific Issues and Workarounds Concerning Solaris (Continued)
TABLE 6
CR ID
Description
6572593
fmdump(1M) may show wrong faulty
component when IOU hardware error occurs.
6584984
On SPARC Enterprise M8000/M9000 servers,
busstat(1M) command may cause rebooting
of domains.
6588650
On occasion, the system is unable to DR after
an XSCF failover or XSCF reboot.
6589833
The DR addboard command might cause a
system hang if you are adding a Sun
StorageTek Enterprise Class 4Gb Dual-Port
Fibre Channel PCI-E HBA card (SGXPCIE2FC-
QF4) at the same time that an SAP process is
attempting to access storage devices attached
to this card. The chance of a system hang is
increased if the following cards are used for
heavy network traffic:
• X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
• X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
6592302
Unsuccessful DR operation leaves memory
partially configured.
30
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1041 • October 2007
Workaround
Check system status on XSCF.
None available at this time. Do not use
busstat(1M) command.
Check for the availability of a patch for this
defect.
There is no workaround. Check for the
availability of a patch for this defect.
There is no workaround. Check for the
availability of a patch for this defect.
To recover, add the board back to the domain
with the addboard command, then retry the
deleteboard command.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m9000

Table of Contents