Furuno FCV-295 Operator's Manual page 46

Color lcd sounder
Hide thumbs Also See for FCV-295:
Table of Contents

Advertisement

APPENDIX 1 MENU TREE
2
User
System
Range
Key
Lang
Units
NMEA
Calib.
Tests
Reset
User Color (Adjust RGB for each color. The setting range for each color is 0 - 63.)
Default (Yes, No)
Custom (Yes, No)
User Clutter (Color 1 -8: 1 - 50; 6)
Default (Yes, No)
Custom (Yes, No)
[User1]
Screen Layout (
Disp Mode (
: HF, LF, HZm, LZm, Mix
,
: HZm+HF, LZm+LF, LF+HF, LZm+HZm,
HF+Mix, LF+Mix
,
: LZm+LF+HZm+HF
: HZm+HF, LZm+LF)
Zoom Mode (Bottom Lock, Bottom Zoom, Marker Zoom,
Discrim1/2, Discrim1/3)
Target Echo (Normal, Surface, Squid, Deep Sea)
Nav Data Disp (Off, Small, Large)
Nav Data (
,
[User2]
Screen Layout (Same choices as Screen Layout in User1.
Disp Mode (Same choices as User1.
Default is LZm+LF+HZm+HF.)
Zoom Mode (Same choices and default setting as Zoom Mode in User1.)
Target Echo (Same choices and default setting as Target Echo in User1.)
Nav Data Disp (Same choices as Nav Data Disp in User1.)
Nav Data (Same choices as Nav Data in User1. Default is
Range 1 (16 - 9000 ft; 30 ft)
Range 2 (16 - 9000 ft; 60 ft)
Range 3 (16 - 9000 ft; 120 ft)
Range 4 (16 - 9000 ft; 250 ft)
Range 5 (16 - 9000 ft; 500 ft)
Range 6 (16 - 9000 ft; 1000 ft)
Range 7 (16 - 9000 ft; 1600 ft)
Range 8 (16 - 9000 ft; 3000 ft)
Zoom Range (16 - 600 ft; 16 ft)
B/L Range (16 - 600 ft; 16 ft)
Split Range (Off, On)
FUNC Key (Pic. Advance, Interference, Color Erase, Clutter, White Line, White Marker, TVG,
STC, Bottom Zone, A-Scope, Split Range, Auto Shift, Freq Choice, Freq Control)
Key Beep (Off, On)
Language (English, OTHERS)
Depth (m, ft, fa, HR, pb)
Temp (°C, °F)
Speed (kt, km/h, mph)
Wind (kt, km/h, mph, m/s)
Distance (nm, km, sm)
NMEA0183 (Ver 1.5, Ver 2.0, Ver 3.0, Special)
NMEA Port (In/Out, In/In)
NMEA Output (Off, On)
WAAS Setup (Off, WAAS-00 - WAAS-27)
TLL Output (Off, TLL, FURUNO-TLL)
Port Monitor (Set up data ports, by installer.)
Sound Speed (200.0 - 2000.0 m/s; 1500.0 m/s)
Temp (-20.0°F - +20.0°F; +0.0 °F)
Speed (STW) (-50 - +50%; +0%)
Bottom Level (-100 - 100; 0)
Zero Line (Off, On)
Zero Line Area (4.5 - 9.8 ft; 4.5 ft)
[HF]
Draft (-15.0 - +50.0 ft, +0.0 ft)
Gain ADJ (-20 - +20, +0)
[LF]
Draft (-15.0 - +50.0 ft, +0.0 ft)
Gain ADJ (-20 - +20, +0)
Test
LCD Test
Factory Reset (Yes, No)
AP-3
,
,
,
,
,
,
,
)
: HZm+HF, LZm+LF, LF+HF, LZm+HZm,
HF+Mix, LF+Mix, HF2+HF1, LF2+LF1
: LF+HZm+HF, LZm+LF+HF, LF+HF+Mix
,
)
Default is
.)
.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents