4-6-2. Self-diagnostic mode
1. Set the TEST MODE.
2. With all the LCD display segments blinking on the set, press
DISPLAY key and the Self-diagnostic mode is entered.
001 1 A d r s
History code
Error display code
3. Hereinafter, each time > N key is pressed, the reference
information display changes as follows:
0XX 1
0XX N
0XX N1 # # # #
0XX N2 # # # #
0XX
R
• Press . key to go back to the previous display.
• Description of the error display codes
Contents of fault
Display code
No error
Servo system error
TOC error
Power system error
Offset error
4-6-3. Clearing the error display code
After servicing, reset the error display code.
1. Set the TEST MODE.
2. Press the DISPLAY key on the remote control activates the self-
diagnosis display mode.
3. To reset the error display code press X key on the remote con-
trol when the code is displayed.(except for R - - - - display)
(All the data on the 1st, N, N-1 and N-2 will be reset)
4. Press X key on the remote control again.
Simplified contents
# # # #
# # # #
– – – –
Meaning of code
00
No error
01
Access target address illegally specified
02
HIGH TEMP
03
FOCUS ERROR
04
SPINDLE ERROR
11
TOC ERROR
12
READ DATA ERROR
22
LOWBATT
31
OFFSET ERROR
32
FE_ABCD_OFFSET_ERR
33
TE_ABCD_OFFSET_ERR
34
X1_TE_OFFSET_ERR
• Contents of the history codes
History code number
1
The first error that occurred.
N
The last error that occurred.
N-1
The first error from the last one.
N-2
The second error from the last one.
Total recording time ( – – – – is displayed
R
for MZ-E900)
Simplified
contents
– – – –
No error
Adrs
An attempt to access an abnormal address.
Temp
HIGH TEMP
Fcus
Focus off-center.
Spdl
Abnormal rotation of disc
TOC
Data
LBat
Instantaneous interruption detected.
Ofst
Offset error
ABCD
FE ABCD Offset error
TE
TE ABCD Offset error
X1TE
X1 TE ABCD Offset error
MZ-E900
Contents
Description
9