Using Remote Surveillance

ALARM

The Alarm tab allows you to configure alarm
settings as well as set motion detection.
To open Alarm setup:
• Click SETUP at the top of the main screen
and then click ALARM.
Figure 28.0 Record menu
Configure the following alarm and motion
detection settings for each respective channel:
NOTE:
NEXT/PREVIOUS
Click
additional channels (8-channel models
only)
• I/O ALARM: Select NO (normal open), NC
(normal close) or OFF
• MOTION DETECT: Configure the following:
• STATUS: Select ON/OFF to enable/disable
motion detection
• SENSITIVITY: Select HIGHEST, HIGH,
NORMAL, or LOW
• MD (motion detection) AREA: Click SETUP to
open the Motion Grid (see Motion Grid on page 36)
• VIDEO LOSS: Select ON/OFF to enable/
disable the alarm when a camera is
disconnected
• HDD SPACE: Select ON/OFF to enable/
disable the alarm when the hard drive is
full (Overwrite must be turned off)
• HDD LOSS: Select ON/OFF to enable/
disable the alarm is the internal hard drive
is damaged or incurs failure
• ALARM MANAGE: Configure the
following:
• OUTPUT: Set the time (in seconds) for the
buzzer to sound when an alarm is triggered—0s,
10s, 20s, 40s, or 60s
34
• POST REC: Set the time for the system to record
after an alarm is triggered—30s, 1min, 2min, or
5min
Click APPLY to save your settings and then
click OK in the confirmation window.

MOTION GRID

To set the motion grid:
1. Click SETUP at the top of the main screen
and then click ALARM.
2. Under MOTION AREA, click SETUP for
each respective channel you wish to apply
motion detection. The Motion Grid opens.
NOTE: Click
channels (8-channel models only).
for
Figure 28.1 Motion Grid
3. Click the blocks to enable/disable motion
detection. RED=motion detection
BLACK=motion detection
click and drag to select multiple blocks;
click CLEAR to disable all the blocks.
4. Click CONFIRM and then click OK in the
confirmation window.