Clearances - Vermont Castings KHLDV400 Installation And Operating Instructions Manual

Khldv series direct vent gas fireplace
Table of Contents

Advertisement

cLearanceS

cLearanceS to coMBuStIBLeS
12" 
(305 mm)
Max. Depth
72" (1829 mm)
Minimum 
Ceiling
6"
(152 mm)
Min.
FP2128
Figure 4 -
FP2128
Clearances from the mantel, ceiling, and side wall.
mantel clearances
ManteL cLearanceS
note: the combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
73D0024
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
the appliance cannot be installed on a carpet,
tile or other combustible material other than
wood flooring. If installed on carpet or vinyl
flooring, the appliance shall be installed on
a metal, wood or noncombustible material
panel extending full width and depth of the
appliance.
2
/
" Max Depth
1
2
(64 mm)
16" (406 mm)
Min. From Opening
10" (254 mm)
 Min.From Opening
Hearth 8" Min.
(203 mm)
Noncombustible
FP2129
Fireplace Opening
KHLDV Series Gas Fireplace
Wall
12" (305 mm)
6" (152 mm)
16"
2
/
" (64 mm)
1
(406 mm)
2
12"
(305 mm)
10"
(254 mm)
Top of Fireplace
Opening
Side View
FP2204
mantel clearances
1"
2
/
"
1
2
3"
5"
6"
top View
Figure 5 -
Mantel clearances
FP2129
mantel leg
Stud
Insulation
Board
Standoff
FP2235
1
/
"
1
2
3
/
"
1
2
4
/
"
1
2
45°
9