9. Cloning and Packet Operation

9.1

Cloning

The memory data and customized operational parameters can be transferred from a
Master unit to other DJ-V57 (Slave units).

9.1.1 Cable Connection

• Make sure that both units are turned off before connecting the cable.
• Connect the Microphone/Speaker jack on the Master unit with the Slave unit using
an optional clone cable (EDS-11) as shown below, then turn on both units.
To the MIC/SP jack on the Master unit
* Be sure to securely screw the plug all the way down to the bottom of the jack.

9.1.2 Master/Slave Units

Press the PTT key three times while holding down
the MONI key.
"CLONE" is displayed on the LCD.
NOTE:
This operation is required also to program the data using utility software.
9.Cloning and Packet Operation
To the MIC/SP jack on the Slave unit