NOTE: For 9851i single stage heat
pump applications, place a jumper
between the W1 and Y1 terminals.
Thermostat
TERMINAL DESIGNATIONS
C - Common 24 VAC
R - System transformer
Y1 - 1st stage cooling
C
Jumper
R
W1- 1st stage heating
Y1
W2- not used
E/W1
Y2 - not used
D
L - not used
W2
Y2
O - Cool active reversing valve
L
B - Heat active reversing valve
H O B G
G - Fan relay
98
1
5
i
D - Dehumidification relay
H - Humidification relay
C
R
Y1
W1
C
L
G
Humidifier
Pump
B
O
H
D
* Please refer to heat pump and
Wiring
furnace installation manuals for
proper terminations
Terminals*
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
1 1
Replace cover on thermostat.
Turn on power to unit and proceed
with programming per instructions on
the display or in the user's manual.
8
Connect wiring between unit and
furnace. For Model 9865i
(2H/2C furnace applications):
Thermostat
C
R
Y1
E/W1
D
W2
Y2
L
H O B G
98
6 5
i
C
Heat
Humidifier
H
* Please refer to furnace
installation manual for
proper terminations
Wiring Terminals*
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
Set Your Name
12
To set your name and phone
number into the thermostat press
MENU, select INSTALLER
SETTINGS, and CONTACT
INFORMATION. The screen at the
bottom left should appear.
To enter your name press EDIT.
Use the UP or DOWN button to
scroll through the characters.
(DOWN gets you to the letters
faster.) After each letter press NEXT.
When you are done entering your
name, press ACCEPT.
CONTACT INFORMATION
BACK
EDIT
9
Connect wiring between unit and heat
pump. Jumper W2 to E/W1 for control
of auxiliary heat in both 2
emergency modes. For Model 9870i
TERMINAL DESIGNATIONS
(2H/2C heat pump applications):
C - Common 24 VAC
R - System transformer
Y1 - 1st stage cooling
W1- 1st stage heating
W2- 2nd stage heating
Y2 - 2nd stage cooling
L - not used
O - Cool active reversing valve
B - Heat active reversing valve
G - Fan relay
D - Dehumidification relay
H - Humidification relay
H O B G
C
R
Y1
W1
W2
Furnace
C
Y2
L
Humidifier
G
H
B
O
* Please refer to heat pump and
furnace installation manuals for
D
proper terminations
Note: To avoid electrical problems, use the system transformer for both
the thermostat and humidifier.
Set Your Phone Number
13
Now enter your phone number.
Use the UP and DOWN arrow to
select the first number. Press NEXT.
When you have completed entering
your phone number, press ACCEPT.
The screen will return to the
INSTALLER SETTINGS. Finish
setting the thermostat for the
application.
CONTACT INFORMATION
AIR EXPERTS
1
ACCEPT
CONTACT INFORMATION
AIR EXPERTS
ACCEPT
NEXT
10
stage and
nd
TERMINAL DESIGNATIONS
Thermostat
C
- Common 24 VAC
R
- System transformer
Y1
- Compressor output
E/W1 - Emergency heat relay
C
R
W2
- 2nd stage heating
Y1
Y2
- 2nd stage cooling
E/W1
L
- System check
D
O
- Cool active reversing valve
W2
Y2
B
- Heat active reversing valve
L
G
- Fan relay
D
- Dehumidification relay
98
7
0
i
(to DS terminal)
H
- Humidification relay
(to Humidifier)
C
R
Y1
E/W1
W2
Heat Pump
Y2
L
G
B
O
D
Wiring
Terminals*
CONTACT INFORMATION
AIR EXPERTS
1-555-555-1212
NEXT
ACCEPT
NEXT
Climate Controls Americas
515 South Promenade Avenue
Corona, CA 92879-1736
United States of America
Made in Mexico
www.about-i-series .com
Connect wiring between the thermo-
stat and the indoor sensor (9020i)
and the outdoor sensor (9025i), if
used. Use twisted pair wiring (22AWG
minimum) with a maximum length of
300 feet (or 100m).
Recycling Thermostat
If this thermostat REPLACES a thermostat that contains
mercury, DO NOT discard the old thermostat in the regular
trash. Mercury is harmful to humans and the environment.
For this reason, do not open, break, or crush the mercury cell.
If mercury leaks from a damaged cell, DO NOT touch or handle
mercury with bare hands. Use protective, non-absorbent
gloves to place mercury into a sealable container. Fill the
container with sand or another absorbent material and seal
the container completely.
Return the mercury or mercury products, in a sealed container,
to Invensys Climate Controls or a local recycling center for
proper disposal. If you have any questions, call Robertshaw
technical support at 1-800-445-8299.
Invensys Climate Controls
28C Leigh Fisher Blvd.
El Paso, TX 79906
Attn: Mercury Recycling Center