3-4.

VIDEO SYSTEM ADJUSTMENTS

Video system adjustments must be performed in the following order.
[Adjusting Order]
1.

28MHz origin oscillation adjustment

2.

AFC f

adjustment
0
3.
Filter f
adjustment
0
4.
Y OUT level adjustment
5.
C OUT level adjustment
6.
REC Y current adjustment
7.
REC C/AFM Current Adjustment
1. 28 MHz Origin Oscillation Adjustment (VC-234 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin ia of IC201 or pin qs of IC501
Measuring Instrument
Frequency counter
Adjustment Pag
F
Adjustment Address
4D
Specified Value
f=14318181 ± 68Hz
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 6, address: 61, and set data: 30.
4) Select page: F, address: 4D, change the data and set the clock
frequency (f) to the specified value.
5) Press the PAUSE button of the adjustment remote commander.
6) Select page: 6, address: 61, and set data: 10.
7) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
VC-234 BOARD
Fig. 5-3-6.
162
109
163
37
48
36
1
IC201
25
12
24
13
IC501
216
1
54
2. AFC f

Adjustment (VC-234 board)

0
Adjust the pull-in range of the A/D converted clock generator during
playback.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 01, set data: 4D, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 6, address: 01, set data: C5, and press the PAUSE
button.
(The AFC fo adjustment is performed and the adjustment data
is stored in page: F, address: 65.)
4) Select page: 6, address: 02, and check that the data is "01".
5) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
6)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
7)
Select page: 0, address: 01, and set data: 00.
108
55
5-44
VTR stop
No signal
Display data of page: 6, address: 02
Adjustment remote commander
F
65
01