Rec Y Current Adjustment (Vc-234 Board) - Sony CCD-TR317 Service Manual

Handycam & handycam vision video camera recorder video 8 / hi8 xr
Hide thumbs Also See for CCD-TR317:
Table of Contents

Advertisement

6. REC Y Current Adjustment (VC-234 board)

Adjust the Y FM signal recording current.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN982 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
6A, 6B
Specified Value
A=235 ± 5mV
Note: PLAYER model:
CCD-TR317/TR517/TRV17/TRV37/TRV47/TRV57/TRV57P/
TRV67
Preparations only for the PLAYER model:
1)
Select page: 0, address: 01, and set data: 01.
2)
Only for the PLAYER model, select page: D, address: 14, after
memorizing the data, set the bit value of bit1 to "1". (Refer to
"4-3, 3. Bit value discrimination" of "5-4. Service Mode").
3)
Select page: D, address: 15, and memorize the data.
4)
Only for the PLAYER model, select page: D, address: 15, and
set the bit value of bit7 to "0".
5)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR, or connect Pin od of IC803
of VC-234 board and GND with 4.7kΩ resistor for a second.)
4.7kΩ resistor: 1-249-425-11
Adjusting method:
1)
Insert a tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: E, address: FB, set data: 06, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: F, address: 71, after note down the data, set data:
00, and press the PAUSE button.
5)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 6, address: 63, and set data: 01.
7)
Select page: F, address: 6B, change the data and set the Y signal
level (A) to the specified value.
8)
Press the PAUSE button.
9)
Select page: F, address: 6A, and set the same data as page: F,
address: 6B, and press the PAUSE button.
10) Select page: F, address: 71, set the data noted down at step 4),
and press the PAUSE button.
11) Select page: E, address: FB, set data: 04, and press the PAUSE
button.
12) Select page: 6, address: 63, and set data: 00.
13) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
14) Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for for the PLAYER
model:
1)
Select page: 0, address: 01, and set data: 01.
2)
Only for the PLAYER model, select page: D, address: 14, and
set the data memorized at step 2) of "Preparations only for the
PLAYER model".
3)
Press the PAUSE button.
4)
Only for the PLAYER model, select page: D, address: 15, and
set the data memorized at step 3) of "Preparations only for the
PLAYER model".
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
0.18 µ sec
VC-234 BOARD
5-47
A
Fig. 5-3-10.
50
26
51
IC803
75
76
100
Fig. 5-3-11.
25
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents