5. Add next sections of pipe until end
penetrates roof line. Check to see that
proper clearances are maintained. Extend
chimney by adding sections of double wall
pipe until pipe is minimum of 30" above
highest point of roof cutout. Termination
and chimney must extend a minimum of
36" above highest point where it passes
through roof.
17" Min.
1" Min.
1" Min.
Pitch
Slope
Flat
0-6/12
26.6°
6/12-
45.0°
12/12
Roof Opening 36" Models
19.5" Min.
2" Min.
2" Min.
Pitch
Slope
Flat
0-6/12
26.6°
6/12-12/12
45.0°
Roof Opening 42" and 50" Models
Figure 15 - Roof Opening Measurements
126595-01A
VENTING INSTALLATION
1" Min.
Opening "A"
Opening
Used Flashing
"A" Max.
Model No.
17"
V6F-10DM
19"
V6F-10DM
24"
V12F-10DM
2" Min.
Opening "A"
Opening
Used Flashing
"A" Max.
Model No.
19.5"
V6F-10DM
22'
V6F-10DM
27"
V12F-10DM
www.SuperiorFireplaces.US.com
Continued
FLASHING INSTALLATION (V6F-10DM
OR V12F-10DM)
Determine the flashing to be used with the roof
opening chart. Slide flashing over pipe until
base is flat against roof. Replace as many
shingles as needed to cover exposed area
and flashing base. Secure in position by nail-
ing through shingles (see Figure 16). DO NOT
NAIL THROUGH FLASHING CONE.
Installing Flashing on a Metal Roof
When installing the flashing on a metal roof,
30" Min.
it is required that putty tape be used between
the flashing and the roof. The flashing must be
secured to the roof using #8 x 3/4" screws and
then sealed with roof coating to prevent leak-
age through the screw holes. A roof coating
must also be applied around the perimeter of
the flashing to provide a proper seal.
Storm Collar
Flashing
Cone
Nail Only
Outer
Perimeter
of Flashing
Underlap Shingles
30" Min.
at Bottom
Figure 16 - Flashing Installation
Storm Collar Installation (SC2-1)
Place storm collar over pipe and slide down
until it is snug against the open edge of the
flashing (see Figure 17). Apply waterproof
caulk around the perimeter of the collar to
provide a proper seal.
Chimney
Pipe
Storm
Collar
Figure 17 - Storm Collar
Overlap
Shingles Top
and Sides Only
Waterproof
Caulk
Flashing
11