Toshiba RAS-10UKV-E Service Manual page 38

Split wall type air-conditioner
Table of Contents

Advertisement

9-1-1. Installation Diagram of Indoor and Outdoor Units
5
Zeolite filter
Before installing the wireless
remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2 Wireless remote control
Cover
3 Batteries
8
6
Flat head wood screw
Purifying filter
4
Remote control holder
2
Wireless remote
control
As shown in the figure, hang power cord
and connecting cable downward, and
take out it along piping connection port.
Fig. 9-1-1
– 37 –
FILE NO. SVM-02007
For the rear left and left piping
Hook
1
Installation
plate
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for better
operation.
Do not allow the drain hose to
get slack.
Shield pipe
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected the left, rear left,
rear right, right, bottom right or
bottom left.
Right
Rear right
Saddle
Insulate the refrigerant
pipes separately with insulation,
not together.
Extension
drain hose
(Option:
RB–821SW)
6 mm thick heat resisting
polyethylene foam
Wall
Cut the piping hole
sloped slightly
Rear left
Bottom right
Left
Bottom left