8-2-3. DRY operation
([MODE] button on the remote control is set the
Dry ( ) operation.)
• Once the setting is made, the operation mode is
memorized in the microcomputer so that the same
operation can be effected thereafter simply by
pushing [START/STOP] button.
• Dry operation signal is transmitted to outdoor unit.
• The Cooling operation giving priority to dehumidifying,
which restrains the indoor fan speed and compres-
sor motor speed, is performed.
• The indoor fan motor operates as shown in Fig. 8-2-5.
(Fan speed is AUTO only.)
• The outdoor unit controls the outdoor fan relay R01,
R02 and R03, and the compressor motor speed
according to the operation command signal sent
from the indoor unit.
+2.5
+2.0
+1.5
+1.0
+0.5
Set
0
temp.
-0.5
NOTE :
*1
: Middle motor speed between L– and SUL
SUL : Super ultra Low
Fig. 8-2-5 Setting of air flow
8-2-4. Heat operation
([MODE] button on the remote control is set the
Heat ( ) operation.)
Transferring of heat operation signal from indoor unit to
outdoor unit starts.
The indoor fan motor operates by the room tempera-
ture when selecting "AUTO" of "FAN" as shown in Fig.
8-2-6, and operates with a set air flow when selecting
"LOW
" to "HIGH
However, to prevent cold draft, revolution speed of the
fan is restricted by indoor heat exchanger when air flow
is AUTO (Fig. 8-2-7) and starting of FAN Manual.
[Basic control]
Set
temperature
L-
*1
*1,*2, *3 : Approximate revolution speed of M
SUL
linear accordingly to temperature.
[Cold draft preventing control]
The upper limit of fan revolution speed is shown below.
46
34
45
33
33
21
32
20
*2
*2
A+4
A+4
A–8
A–8
FAN
Starting
AUTO
of FAN
Manual
Fig. 8-2-7 Cold draft preventing control
NOTES :
*1 : Stops for 2 minutes after thermostat-OFF.
*2 : 24°C when the set temperature is 24°C or more
Set temperature when the set temperature is
below 24°C
– 27 –
FILE NO. SVM-02007
".
0
-0.5
-1
-1.5
-2
-2.5
-5.0
-5.5
[FAN AUTO]
Fig. 8-2-6 Setting of air flow
HIGH
Approximate
revolution speed
of HIGH and SUL
linear by Tc.
SUL
SUL (NOTE : *1)
Stop
LOW
* 1
* 2
* 3
+
M
HIGH
+
and L to