27,000Btu/h
Indoor unit
Outdoor unit
AM27B1C07
UM27B1C3
AM27B1C13
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
100 mm
(4 inch)
or more
600 mm (24 inch)
minimum
100 mm
(4 inch)
minimum
600 mm
(24 inch)
minimum
Piping length and the height.
Pipe size
MAX. piping length
Unit
Liquid
GAS
A-unit
1/4
"
"
15 m (49ft. 3in)
1/2
B-unit
15 m (49ft. 3in)
"
3/8
"
1/4
C-unit
15 m (49ft. 3in)
"
1/4
"
3/8
Power supply
Ø, V, Hz
1,208-230~,60
B-unit
7,000 Btu/h
25 mm (1 inch)
or more
A-unit
13,000 Btu/h
A
(15 m (49ft. 3in)
100 mm
(4 inch)
minimum
A
B
Circuit breaker
(20A)
MAX. height
A
B
7 m (23ft)
7 m (23ft)
7 m (23ft)
C-unit
7,000 Btu/h
160 mm
(6 inch)
or more
maximum)
Main power switch
P
I
REPARING THE
NSTALLATION
B
(7 m (23ft) maximum)
INDOOR UNIT
A
B
OUTDOOR UNIT
31
E-