Programming
The following sections list Axcess programming commands used with the AXB-VOL3.
Channel Settings Commands
Use the AXB-VOL3 channel settings listed for ramp up, ramp down and mute operations..
AXB-VOL3 Channel Setting Commands
Channel Description
1
2
3
4
5
6
Ramping a volume channel while the mute channel is on will NOT automatically turn
off the mute channel (will not restore) but the ramping will still occur and the volume
change will be noticed when the mute channel is turned off. For setting ramp rates
and presets, see SEND_COMMAND programming instructions below. For reading
current volume levels and displaying bargraphs see CREATE_LEVEL and
SEND_LEVEL programming instructions. Volume channels 1 through 3 use levels 1
to 3 respectively.
When controlling levels, such as with an active bargraph, there is no LED indication of volume
changes.
Levels
AXB-VOL3 Three-Channel Volume Control
Ramps channels 1 and 2 up.
Ramps channels 1 and 2 down.
Mutes channels 1 and 2.
Ramps channel 1 up.
Ramps channel 1 down.
Mutes channel 1.
1 = Output #1
2 = Output #2
3 = Output #3
Channel Description
7
Ramps channel 2 up.
8
Ramps channel 2 down.
9
Mutes channel 2.
10
Ramps channel 3 up.
11
Ramps channel 3 down.
12
Mutes channel 3.
Programming
5