Door Lock - Unlocked Position
Strip Circuit
THERMAL SW
Y
BU
UNLOCK SW
Y
UNLOCKED
To remove the lock assembly on single and upper
double ovens:
1.
Access the control compartment. (See
.)
Compartment Access
2.
Hold control panel and open oven door.
3.
Place the control panel on a protected oven
door as shown.
LOW TEMP
BU
4
O
5
LOCK SW
6
Control
4.
Mark and disconnect connectors from the lock
assembly.
5.
Remove 2 hex-head screws and the lock
assembly from the oven.
Caution: It is possible to reconnect the switch wiring
incorrectly to the lock assembly. When reconnecting
the wiring, make sure it is properly connected to the
lock assembly before turning the power back on.
To remove the lock assembly on lower double
ovens:
1.
Access the lower control compartment. (See
Lower Oven Control Compartment Access
2. Open lower oven door.
3. Remove 2 Phillips-head screws from the door
lock assembly.
4. Mark and disconnect connectors from the lock
assembly.
Caution: It is possible to reconnect the switch wiring
incorrectly to the lock assembly. When reconnecting
the wiring, make sure it is properly connected to the
lock assembly before turning the power back on.
– 28 –
Lock Assembly
.)