Glossary; Fcc Information; Underwriters Laboratories Information; Specifications - Interlogix NetworX NX-1700E Installation And Startup Manual

Proximity card reader
Table of Contents

Advertisement

IX.

GLOSSARY

TERM
Alternative Mode
Double
Beep...................
Double Beep Scan...........
Legacy Mode..................
Request
To
Exit
(RTE)......
Scan............................
Single Beep....................
Single Beep Scan............
Triple Beep.....................
Triple Beep Scan.............
X.

FCC INFORMATION

This device complies with Part 15 of the FCC rules. Operation is subject to the following three conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
FCC ID: CGGNX-1700E
XI.

UNDERWRITERS LABORATORIES INFORMATION

The NX-1700E module has received UL listing:
XII.

SPECIFICATIONS

DIMENSIONS
OPERATING POWER
CURRENT DRAW
OPERATING TEMPERATURE
SHIPPING WEIGHT
Main
Outside the US
NX-1700E Card Reader
Alternative mode is an optional scan method, as opposed to the default Legacy mode (see below).
The card is to be continuously held at the reader for a specified number of beeps. Example: Hold
the card at the card reader's sensor for a total of 2 beeps. This is a "double beep" in the Alternative
mode.
This method becomes available when Location 272, Segment 1, Option 6 is disabled.
An audible indicator (beep, beep).
When a user card is scanned and held at the reader for 2 beeps, the reader will perform the functions
as programmed in Location 241, Segment 4.
Legacy mode is used to describe the default operation of the card reader's scanning method. This
mode uses the same scan methods as prior versions of the card reader modules. Example: Pass a
user card by the reader's sensor, remove it from the field, then pass the card by the reader's sensor
once again during the time programmed in Location 244, Segment 1. This is a "double scan" in the
legacy mode.
A zone can be programmed to monitor an open door. The RTE activates the onboard open collector
output and sends a message on the buss.
To "present" or pass a card or FOB within sensing range of the card reader module.
An audible indicator (beep).
When a user card is scanned and held at the reader for 1 beep, the reader will perform the functions
as programmed in Location 241, Segment 3.
An audible indicator (beep, beep, beep).
When a user card is scanned and held at the reader for 3 beeps, the reader will perform the functions
as programmed in Location 241, Segment 5.
800-727-2339
903-845-6941
DESCRIPTION
UL294 Access Control Systems Units
Approx. 1.5"W x 4.5"L x 1"D with 6' cable
12 VDC, Supplied by NX-6, NX-8, NX-8E, or NX-320E
40mA Standby with Green LED
110mA
Maximum
-31 to +151 degrees F
5 to +66 degrees C
< 1 lb.
1420 N. MAIN STREET; GLADEWATER, TEXAS 75647
Technical Support
Sales & Literature
888-437-3287
800-547-2556