Epson Stylus Photo PX650/TX650/TX659/PX660/PX660 Premium/Artisan 635
Category
Error Code
Maintenance
A0H
Waste ink overflow
error
88H
Inserted tray error during cleaning
Abnormal
operation
Obstruction detection error during
89H
cleaning
TROUBLESHOOTING
Table 3-3. Fatal Errors (continued)
Error
Cause
Life expiration of maintenance
parts
An error occurred during
cleaning
Troubleshooting When There is Error Display
Remedy
Replace all the maintenance parts, and clear the maintenance counter.
(Refer to "6.1.1 Maintenance Error"
(p.131).)
Pulling out the CDR Tray
Checking the CDR Tray Sensor (p.36):
Checking the CDR Tray Sensor for adhesion of dirt or dust
Checking the connection of the connector of the CDR Tray Sensor
Checking the connection of the FFC
Checking the following parts and replace the defective one:
CDR Tray Sensor
(p.36)
CDR Tray
Checking the operation of the CR Unit:
Move the CR Unit by hand, and check to see if it moves smoothly.
Checking the following parts and replacing the defective one:
Checking the lead wires of the CR Motor (CN14) for disconnection or breakage
Checking the CR Encoder FFC (CN16) for disconnection or breakage
Checking the printer frame for adhesion of dirt or insufficient lubrication
Checking the CR Guide Shaft for adhesion of dirt or insufficient lubrication
Checking the Linear Scale for adhesion of dirt or damage
Checking the CR Encoder for adhesion of dirt or damage
Checking the CR Belt for damage or improper tension
Checking the CR Motor and replacing it if necessary
Main Board
(p.78)
Revision C
(p.135)
(p.134)
(p.87)
(p.36)
(p.96)
(p.96)
50
Confidential