6.

Fault diagnosis/ What to do if ...?

6.1

Alarmmanagement (Faultcodes)

Alarmmanagement Powerboards Prisma, OVC1000 und OVC2000
Display
Description of fault
Internal error
F0
F1
door cannot be locked
door cannot be unlocked
F2
F3
software error
Temperature sensor alarm - resulting in F4
F94
F4
Temperature sensor without contact or short circuit Test temperature sensor, replace if necessary
Clotted heating element relay contacts on the
F5
power electronics
F95
Temperature alarm at power electronics - resulting
in F6
Temperature alarm at power electronics - resulting
F96
in F6
Power electronics temperature too high
F6
F7
Faulty electrical connection (only in appliances
with Prisma power electronics)
No connection between power electronics and
F8
input electronics
F9
Micro processor resets itself independently (=
Reset)
F10
Triac on power electronics defect
F11
Meat skewer sensor without contact or short-
circuited
F91
Temperature sensor alarm for steam generator -
resulting in F12
Temperature sensor of steam generator without
F12
contact or short-circuited
Internal electronics error
F13
software error
F14
F15
Internal electronics error
Combined alarm Pyrolytic cleaning/cooking zone
F16
DGS-TDS-N 05.09 A. B. © Electrolux
Fault repair
replace power electronics
Test door locking system
Test door locking system and unlocking thermostat
f11
Execute network reset by disconnecting the
appliance from the electricity supply and restarting
Test temperature sensor, replace if necessary
Replace power electronics
Test built-in situation of the ventilation channel and
the function of the cooling fan
Test built-in situation of the ventilation channel and
the function of the cooling fan
Test built-in situation of the ventilation channel and
the function of the cooling fan
Correctly connect the appliance and re-start
Check connection line - replace electronic systems if
necessary
Execute network reset by disconnecting the
appliance from the electricity supply and restarting
Activate Main Button, select an operation modus
with hot air, wait for cooling ventilation start, replace
power electronics again in the event of an error report
following approximately 20 seconds
Check meat thermometer, also check bushing and
wiring if necessary; if all this OK replace power
electronics
Test temperature sensor, replace if necessary
Test temperature sensor, replace if necessary
Replace power electronics
Replace input electronics
Replace input electronics
Replace input electronics