Manual Operation - Harman Accentra Freestanding Pellet Stove Installation & Operating Manual

Accentra freestanding pellet stove
Hide thumbs Also See for Accentra Freestanding Pellet Stove:
Table of Contents

Advertisement

Fig. 5
Room Temperature Mode: This setting will produce a room temperature
of 70 degrees with the distribution blower at medium speed.
manual Stove Temperature mode
This setting will produce a large viewing fire without a distribution
blower operating.
Fig. 6
Shut-down Procedure
Turn the Mode Selector to "OFF". This will allow the fire to diminish and burn out. When the fire burns out and the ESP cools,
everything will stop. Never pull the plug to shut down the stove. This will cause incomplete combustion and smoke in the
firebox. If the load door is opened the smoke may escape.
The best way to shut down the stove is simply let it run out of pellets, then the stove will shut down automatically.
3-90-05471_R15_05/14
manual Ignition/Operation
The Accentra Pellet Stove is capable of manual operation.
This allows the operator to manually control operation and
fuel consumption. Manual operation can also be helpful
during an emergency (i.e. igniter failure, or when using certain
generators.) The unit can be switched between "AUTO" and
"MANUAL" at any time during operation.
NOTE: when starting the unit in the "AuTO" mode,
switching to "mANuAl" can be done at any time. Once
an ignition cycle is started, it will continue, regardless
of mode. There is no need to wait for the ignition cycle
to complete.
Igniter Switch to "mANuAl"
room Temperature mode
The fire will have to be lit with starting gel and a match, or
started automatically, see "Automatic Operation". Turn to
"Manual" position when the fire is established.
The difference between "AUTO" Room Temperature Mode
and "Manual" Room Temperature Mode is that the fire will not
go out as the room temperature goes above the control board
setting. The unit can only go to low burn and will remain there
until it runs out of fuel or until more heat is needed and the
feed rate increases. Feed rate adjustments and dial settings
are the same as "AUTO" settings.
Igniter Switch to "mANuAl"
Stove Temperature mode
The advantage of this mode is to allow the operator to have
a large viewing fire without blowing extra heat into the room.
During operation, with the temperature dial set at #4 or less,
the distribution fan will not operate. A #3 on the temperature
dial and a #4 on the feed adjuster is approximately 80%
output. The distribution blower will not operate below this
point. Therefore, there can be a higher feed rate ( a larger
viewing fire) without an excess of hot air blowing into the
room.
An example of when to use the Manual Stove Temperature
Mode is if you want to watch a large fire and the room is
already up to temperature. The Stove Temperature Mode
allows you to have a larger fire and a lower sound level,
without the distribution blower.
NOTE: during the use of this mode, if you keep increasing
the temperature dial setting to increase the fire size, the
distribution blower will automatically come on when the
ESP Temperature reaches 350
F, or 81% output.
°