Manual Operation - Harman XXV Pellet Stove Installation & Operating Manual

Xxv pellet stove
Table of Contents

Advertisement

Fig. 24
Manual Stove temperature Mode
This setting will produce a large viewing fire without
a distribution blower operating.
Manual ignitiOn/OPeratiOn
The XXV Pellet Stove is capable of manual operation. This also allows the operator
to manually control operation during an emergency (i.e. igniter failure, or when using
certain generators.)
The unit can be switched between "AUTO" and "MANUAL" at any time during
operation.
Room Temperature Mode:
This setting, see below, will
produce a room temperature of
70 degrees with the distribution
blower at medium speed.
Fig. 25
nOte: when starting the unit in "autO" mode
and switching to "Manual": Once an ignition cycle
has started, it will continue regardless of mode.
Switching from "auto" to "Manual" can be done as
soon as the igniter light comes on.
igniter Switch to "Manual"
room temperature Mode
The fire will have to be lit with starting gel and
a match, or started automatically, see "Automatic
Operation" on Page 20. Turn to "Manual" position after
the ignition cycle starts.
The difference between "AUTO" Room Temperature
Mode and "Manual" Room Temperature Mode is that
the fire will not go out as the room temperature goes
above the control board setting. The unit can only go to
low burn and will remain there until it runs out of fuel or
until more heat is needed and the feed rate increases.
Feed rate adjustments and dial settings are the same as
The blower will shut off completely
"AUTO" settings.
if the temperature on the ESP is too low.
igniter Switch to "Manual"
Stove temperature Mode
The advantage of this mode is to allow the operator
to have a large viewing fire without blowing extra heat
into the room.
During operation, with the temperature dial set at
#3 or less, the distribution fan will not operate. It is not
necessary to operate the distribution blower below this
point. This control setting allows a higher burn rate (a
larger viewing fire) without an excess of hot air blowing
into the room.
An example of when to use the Manual Stove
Temperature Mode is if you want to watch a large fire
and the room is already up to temperature. The Stove
Temperature Mode allows you to have a larger fire and
a lower sound level, without the distribution blower.
nOte: during the use of this mode, if you
keep increasing the temperature dial setting to
increase the fire size, the distribution blower will
automatically come on when the eSP temperature
reaches 350
F, or 81% output.
o