Troubleshooting - Central Pneumatic 95275 Set Up And Operating Instructions Manual

Three gallon oilless air compressor
Table of Contents

Advertisement

Problem
Compressor
1.
No power at outlet.
does not start
or restart
2.
Power cord not plugged in
properly.
3.
Thermal overload switch
tripped.
4.
Building power supply circuit
tripped or blown fuse.
5.
Tank is already pressurized.
6.
Cord wire size is too small or
cord is too long to properly
power compressor.
7.
Compressor needs service.
Compressor not
1.
Compressor not large
building enough
enough for job.
air pressure
2.
Loose fittings.
3.
Hose or hose connections
not adequate.
4.
High altitude reducing air
output.
5.
Check Valve needs
service.
Overheating
1.
Unusually dusty
environment.
2.
Cord is too small of a
gauge or too long to handle
compressor.
3.
Unit not on level surface.
Follow all safety precautions whenever diagnosing or servicing the
compressor. disconnect power supply before service.
Page 12
Possible Causes
For technical questions, please call 1-800-444-3353.

Troubleshooting

1.
Reset circuit breaker, or have outlet serviced by a
qualified technician.
2.
Check that cord is plugged in securely.
3.
Turn off Tool. Turn off Compressor and wait for it to cool
down. Press reset button. Resume operation.
4.
Reset circuit or replace fuse. Check for low voltage
conditions. It may be necessary to disconnect other
electrical appliances from the circuit or move the
compressor to its own circuit.
5.
No problem. Compressor will start when needed.
6.
Use larger diameter or shorter extension cord or
eliminate extension cord. See Recommended Wire
Gauge for Extension Cords in Safety section.
7.
Have unit inspected by a qualified technician.
1.
Check if accessory SCFM is met by Compressor. If
Compressor cannot supply enough air flow (SCFM),
you need a larger Compressor.
2.
Reduce air pressure, then check all fittings with a soap
solution for air leaks and tighten as needed. Do not
overtighten.
3.
Replace with larger hose and/or hose connections.
4.
You may need a larger compressor if you are
situated in a high altitude location.
5.
Clean or replace, as needed.
1.
Move unit to cleaner environment.
2.
Increase cord size or use shorter length extension cord,
or eliminate extension cord. See Recommended Wire
Gauge for Extension Cords in Safety section.
3.
Reposition unit on a level surface.
Likely Solutions