Wiring Diagram

SYMPTOM
Burner will not light
Smell of gas
Fan not working
Small soot deposit
Soot deposit forming on
glass or logs
Condensation on glass
Streaky lines on glass
NOTE:
If you have any other faults or problems, please refer to your Installer or local qualified service
agency
WIRING DIAGRAM

TROUBLE SHOOTING

CAUSE
No power present
No gas present
power cut
Air in gas pipe
Ignition failure
Leaking gas
Heat switch not activated
Fan not turned on
Normal operation
Inadequate flue system
Log misalignment
Incorrect gas pressure
Normal operation
Normal operation
Wiring Diagram Ladder
Caution: Label all wires prior to
disconnection when servicing
controls. Wiring errors can
cause improper and dangerous
operation.
Verify proper operation after
servicing.
SOLUTION
Ensure power cord is plugged in and
turned on
Ensure gas supply is turned on
Re-ignite after power is restored
Purge air (installer)
Repeat lighting procedure
Turn gas off at meter and call installer
Allow fire to run on HIGH for 15 minutes
minimum
Ensure appliance fan switch is in ON
position
No action required
Call service department/agent
Allow fire to warm up
Remove and clean glass