HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils
UNIT
MODEL*
YHJD18S41S1
YHJD24S41S1
YHJD30S41S1
YHJD36S41S1
YHJD42S41S1
YHJD48S41S1
YHJD60S41S1
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
Johnson Controls Unitary Products
1
COIL
MODEL
MBH
FC/MC/PC/UC18
17.0
FC/MC/PC/UC24
17.0
HC18
17.0
HC30
17.0
HD24
16.6
FC/MC/PC32
23.2
FC/MC/PC35
23.2
HC30
23.0
HC36
23.2
HD36
23.2
FC/MC/PC37
28.2
FC/MC/PC43
28.2
HC42
28.2
HD48
28.2
FC/MC/PC37
35.0
FC/MC/PC43
35.0
FC/MC/PC48
35.0
HC42
35.0
HD48
35.0
FC/MC/PC60
41.0
HC60
41.0
HD60
41.0
FC/MC/PC48
50.5
FC/MC/PC60
51.0
HC60
51.0
HD60
50.0
MC62
50.5
MC62
56.5
ARI HEATING
47F
COP
KW
MBH
3.32
1.50
12.7
3.44
1.45
10.4
3.32
1.50
12.7
3.38
1.47
10.4
3.16
1.54
12.8
3.40
2.00
12.6
3.40
2.00
12.6
3.40
1.98
12.6
3.40
2.00
12.6
3.40
2.00
12.6
3.40
2.43
16.6
3.40
2.43
16.6
3.40
2.43
16.6
3.60
2.30
16.6
3.40
3.02
21.2
3.42
3.00
21.2
3.42
3.00
21.4
3.42
3.00
21.2
3.40
3.02
20.0
3.66
3.28
27.8
3.66
3.28
27.8
3.14
3.83
27.6
3.32
4.46
30.8
3.50
4.27
30.6
3.50
4.27
30.6
2.98
4.92
30.6
3.38
4.38
30.6
3.48
4.76
35.4
2
17F
COP
KW
3.00
1.24
2.60
1.17
3.00
1.24
2.60
1.17
3.00
1.25
2.24
1.65
2.24
1.65
2.24
1.65
2.24
1.65
2.24
1.65
2.32
2.10
2.32
2.10
2.32
2.10
2.32
2.10
2.36
2.63
2.36
2.63
2.36
2.66
2.36
2.63
2.16
2.71
2.56
3.18
2.56
3.18
2.26
3.58
2.24
4.03
2.34
3.83
2.34
3.83
2.06
4.35
2.28
3.93
2.42
4.29
HSPF
STD
7.70
7.70
7.70
7.70
7.70
7.70
7.70
7.70
7.70
7.70
7.70
7.70
7.70
7.70
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
13