Rs232 Timeout; Xon/Xoff - Honeywell Vuquest 3310g User Manual

Area-imaging scanner
Hide thumbs Also See for Vuquest 3310g:
Table of Contents

Advertisement

Flow Control with Timeout: The scanner asserts RTS when it has data
to send and waits for a delay (see

RS232 Timeout

on page 2-24) for CTS to
be asserted by the host. If the delay time expires and CTS is not asserted,
the device transmit buffer is cleared and scanning may resume.
Default = RTS/CTS Off.
Flow Control, No Timeout
Two-Direction Flow Control
Flow Control with Timeout
* RTS/CTS Off
RS232 Timeout
When using Flow Control with Timeout, you must program the length of the
delay you want to wait for CTS from the host. Set the length (in millisec-
onds) for a timeout by scanning the bar code below, then setting the time-
out (from 1-5100 milliseconds) by scanning digits from the inside back
cover, then scanning Save.
RS232 Timeout

XON/XOFF

Standard ASCII control characters can be used to tell the scanner to start
sending data (XON/XOFF On) or to stop sending data (XON/XOFF Off).
When the host sends the XOFF character (DC3, hex 13) to the scanner,
2 - 24