York GHD Technical Manual

York GHD Technical Manual

Add - on coils for use with split-system cooling & heat pumps
Hide thumbs Also See for GHD:

Advertisement

Heating
Air Conditioning
TECHNICAL GUIDE
ADD - ON COILS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: GHD, GFD, GFA, GNA,
GUA & GHA
600 - 2000 CFM
2 - 5 TON COILS
HORIZONTAL
FULL CASED
G1HD
MULTI-POSITION
UPFLOW UNCASED
G1NA
HORIZONTAL CASED
G1HA
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
R
G2FD
UPFLOW CASED
G1FA
UPFLOW
G1UA
ISO 9001
Certified Quality
Management System
DESCRIPTION
These cooling and heat pump coils are designed to be
installed with UPG furnaces and to be matched with UPG
cooling and heat pump outdoor units. All coils are available
as sweat-connect models for your convenience and ease of
matching.
Upflow Coils - Available in high-capacity models to match
any system and upflow furnace. Models available with factory
installed TXV or orifice metering system.
Multi-Position Coils - Available in high-capacity models to
match any system and any multi-position furnace and air
handler. Selected models available with factory installed TXV
or standard orifice metering systems. Selected models also
available from the factory with thicker 3/4" cabinet insulation.
Horizontal Duct Coils - Available to match any cooling or
heat pump system and horizontal furnace. Field transition
may be required.
Dedicated Horizontal Cased Coils - Available to match
most cooling or heat pump systems and any horizontal gas
furnace or modular air handler. For horizontal application
only. Models available with factory installed TXV or orifice
metering system.
FEATURES
Insulated Cabinet - All evaporator coil cabinets are thermally
insulated to prevent sweating.
Internally Clean - All evaporator coils are factory leak-
tested, dehydrated, sealed and shipped with a holding
charge.
Durable Finish - Coil casings are made of pre-painted steel.
The pre-treated flat galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep.
Optimum Heat Transfer - Using the latest in heat transfer
technology, staggered rows of rifled copper tubes are
mechanically expanded into aluminum fins to provide opti-
mum air to surface contact for ample moisture removal as
well as high performance ratings.
Optional Factory Installed Thermal Expansion Valve -
Provides flexibility to match high efficiency applications at a
lower installed cost.
Yorkmate Refrigerant Control - Provides optimum system
performance and the flexibility to match coils with any effi-
ciency level cooling or heat pump system.
ACCESSORIES
Refer to Price Manual for specific model numbers.
TXV Kits - Thermal expansion valve kits are available for
indoor coils to obtain specific system performance.
Horizontal Drain Pan Kits - A field installed horizontal drain
pan kit (1HP0623BK or 1HP0628BK) is available for horizon-
tal applications on the multi-position coil. The full cased multi-
position coil is also available with a factory installed horizon-
tal drain pan option.
036-21145-004 Rev. A (0105)

Advertisement

Table of Contents
loading

Summary of Contents for York GHD

  • Page 1 The full cased multi- are subject to change without notice. position coil is also available with a factory installed horizon- Visit us on the web at www.york.com for the most tal drain pan option. up-to-date technical information.
  • Page 2: Table Of Contents

    036-21145-004 Rev. A (0105) COOLING CAPACITY - Coil Only Entering MBH @ Evaporator Temperature and Corresponding Pressure °F / PSIG Rated Air °F Model 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 (Wet Bulb) UPFLOW "A" TYPE 35.6 32.5 29.0...
  • Page 3 036-21145-004 Rev. A (0105) COOLING CAPACITY - COIL ONLY Entering Air °F MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG Model Coil Rated CFM (Wet Bulb) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MULTI-POSITION 36.3 33.0 29.5...
  • Page 4 036-21145-004 Rev. A (0105) COOLING CAPACITY - COIL ONLY MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG Model Coil Rated CFM Entering Air °F (Wet Bulb) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 uncased upflow 27.4 25.0 22.3...
  • Page 5: G1Ua024S14

    036-21145-004 Rev. A (0105) STATIC PRESSURE VS. AIRFLOW (BASED ON WET COIL) Model Airflow Wet Coil Model Airflow Wet Coil UPFLOW CASED "A" TYPE CASED "A" TYPE MULTI-POSITION 0.12 0.10 G1FA024S14(T) 0.21 G2FD024(S,H)14(T) 0.19 G1UA024S14 1000 0.33 1000 0.29 0.10 0.08 G1FA024S17(T) 0.17...
  • Page 6: G1Fa036S14(T)

    036-21145-004 Rev. A (0105) PHYSICAL DATA Refrig. Std. Face Operating Rows Tube Tube Expansion Model Application Conn. Orifice Area Coil Size Weight Deep Geometry Dia. Type Device Types Size (Sq. Ft.) (Lbs.) UPFLOW "A" TYPE G1FA024S14 2.92 (2) 12 x 17.5 Orifice G1FA024S14T 2.92...
  • Page 7 036-21145-004 Rev. A (0105) PHYSICAL DATA (Continued) Refrig. Std. Face Operating Rows Tube Tube Expansion Model Application Conn. Orifice Area Coil Size Weight Deep Geometry Dia. Type Device Types Size (Sq. Ft.) (Lbs.) FULL CASED "A" TYPE MULTI-POSITION G2FD024(S,H)14 3.40 (2) 14 x 17.5 Orifice G2FD024H14T...
  • Page 8 036-21145-004 Rev. A (0105) DIMENSIONS G1FA UPFLOW CASED COIL 20-7/8 20-3/16 Refrigerant Dimensions — Inches Connections Model Line Size Liquid Vapor 14-1/2 13-3/8 13-1/2 G1FA024S14(T) G1FA024S17(T) 17-1/2 16-3/8 16-1/2 G1FA030S14(T) 14-1/2 13-3/8 13-1/2 G1FA036S14(T) 14-1/2 22-1/4 13-3/8 13-1/2 G1FA036S17(T) 17-1/2 19-1/2 16-3/8 16-1/2...
  • Page 9: G1Ua036S21

    036-21145-004 Rev. A (0105) G1UA UPFLOW CASED COIL 20-7/8 20-3/16 Refrigerant Dimensions — Inches Connections Model Line Size Liquid Vapor G1UA024S14 14-1/2 14-1/2 13-3/8 13-1/2 G1UA024S17 17-1/2 16-3/8 16-1/2 G1UA030S14 14-1/2 16-5/8 13-3/8 13-1/2 G1UA036S14 14-1/2 19-7/8 13-3/8 13-1/2 G1UA036S17 17-1/2 18-3/8 16-3/8...
  • Page 10 036-21145-004 Rev. A (0105) G1HD HORIZONTAL DUCT COIL 3-3/4 2-5/8 1-3/8 LIQ UID C ONN. 3/4 MP T S E C ONDAR Y V AP OR DR AIN C ONN. C ONN. 3/4 MP T P R IMAR Y DR AIN C ONN. 1-3/4 1 -3/8 1-7/8...
  • Page 11 036-21145-004 Rev. A (0105) G2FD MULTI-POSITION “A” COIL (Available with or without a factory installed horizontal drain pan). 3/4” FLANGE BOTTOM OPENING Dimensions — Inches Refrigerant Connections Model Quick-Connect Line Size Liquid Vapor Liquid Vapor G2FD024(S,H)14(T) 14-1/2 13-3/8 13-1/2 — —...
  • Page 12 — — — — — — Subject to change without notice. Printed in U.S.A. 036-21145-004 Rev. A (0105) Copyright © by York International Corp. 2005. All rights reserved. Supersedes: 036-21145-003 Rev. D (0504) Unitary 5005 Norman Products York Group Drive...

This manual is also suitable for:

GfaGfdGnaGuaGha