NOTES:
1. SCHEMATIC SHOWS OVEN WITH DOOR OPEN AND WITHOUT POWER APPLIED
DRAWING OF 40-PIN CONNECTOR
EVENS ODDS
MAG
CT
MONITOR (NO) INTER IN
PRIMARY (NO) INTER IN
SECONDARY (NO) INTER IN
BMSC (9) (STATUS OK)
BMSC SEL
ASPEN
P5
-24V MAG THEMO SW RTN
K5 (-B) BOTTOM IR OUT
K6-B (VOLTS MOD OUT)
BMSC (3) (ENABLE OUT)
-24V (VOLT MODULE RTN)
THERMOCOUPLES
RJ11
RJ11
J4
P4
P6
J6
SMART CARD CONNECTOR
SAFETY INTERLOCKS
MONITOR
SWITCH
NC
PRIMARY
C
NO
INTERLOCK
NC
NC
C
C
NO
SECONDARY
NO
INTERLOCK
OR-6
1
1
MAG FAN RELAY
WH-1
2
2
K2-B (MAG OUT)
WH-2
3
3
4
4
5
5
OR-6
6
6
7
7
OR-7
8
8
OR-8
9
9
OR-9
10
10
HX STATUS IN
11
11
MAG THERMO SW IN
OR-11
12
12
13
13
VOLT MODUAL IN
OR-13
QC1
14
14
15
15
OR-11
16
16
+24V PS IN
RD-16
17
17
BK-23
3
6
18
18
19
19
RD-19
20
20
2
5
-24V PS IN
BK-20
DRAWING OF 6-PIN
21
21
-24V P INTER RTN
BK-21
1
4
CONNECTOR
22
22
-24V S&M RTN
BK-22
23
23
BK-23
24
24
BMSC 0-10V OUT
RD-24
25
25
BMSC COMM (2)
RD-25
26
26
27
27
K1-B (MAG FIL OUT)
WH-27
28
28
WH-28
29 29
30
30
K4 (B-) (CONV OUT)
WH-301
31
31
WH-31
32
32
BMSC (4) (COM RTN)
BK-32
33
33
BK-33
34
34
A(-)
35
35
IR
IR
C(+)
36
36
37
37
A(-)
EC
EC
38
38
C(+)
A(-)
39
39
CC
CC
40
40
C(+)
GREEN
4
M3 WHITE
240 VAC
3
M2 RED
2
3 PHASE
M1 BLACK
1
OUT
BMSC
1
0-10V
BLWR
SPD CMD
I/O COMMON
2
MTR
3
ENABLE
3
200-240
I/O COM
4
2
VAC IN
STATUS OK
5
1
I/O COMMON
6
K6 VOLTS
L
+V
RD-20
24VDC
POWER
N
-V
BK-16
SUPPLY
BR420
G
SPLICE 1
MAG
CT
K3 MONITOR
BR400
MAG THERMO
SWITCHES
A
212°F
212°F
NO
NO
C
C
K2 ANODE
QC2
A
K1 FILAMENT
QC3
BL120
RD-19
P IN1
P IN1
BR230
WH-27
P IN2
P IN2
OR-61
P IN3
P IN3
WH-29
P IN4
P IN4
A
WH-2
P IN5
P IN5
P IN6
P IN6
WH-28
WH-301
BL140
BR250
BR210
FAN1 (COOLING)
OT2
BL110
BR220
C
NO
120°F
2
2
2
F1
F2
F3
VOLTAGE MODULE
BR000
1
1
1
BL000
EMI
L
L
FILTER
INP UT
L2
L2
G
F3: 20 AMPS CLASS CC
F2: 12 AMPS CLASS CC
LINE-OUT VIEW
F1: 12 AMPS CLASS CC
ALL OTHER WIRES
ALL BLUE WIRES
BR
T2
BL
OR
DRAWING OF HV TRANSFORMERS
BL150
OR270
1
7
4
BR280
OR440
2
8
BR450
5
3
OR360
6
BL370
9
HV TRANSFORMERS
A
B
1-2 = 208VAC
1-3 = 240VAC
BL355
T2
T1
1
7
4
3
9
M2HV
M1HV
6
B
0.91 uF
0.91 uF
C2
M2CD
M1CD
(-) D2 (+)
(+) D1 (-)
1
7
4
3
M2F
9
M1F
6
B
F
FA
F
FA
1
7
MAG 1
MAG 2
4
BL160
3
NOT
9
NO
NC
A
USED
24V +
6
BR290
WH-1
C
B
MAG_F AN _RELAY
J
K7
B
HX ELEMENT
3300 WATTS
13.1 OHMS
32
31
RD-19
OR540
B
A
22
21
1
HT520
-
+
- +
BL510
BOTTOM IR
SSR
11
12
K5
K4
3000 WATTS
MANUAL RESET
14.4 OHMS
B2
A2
OT1
B1 A1
2
BL500
NGC (US) SCHEMATIC
55
OR
T1
BR
BL
BL340
M2FC
M1FC
1
FT 2
BL150
C1
2
4
BR280
5
3
OR270
1
FT 1
BL155
M2FA
4
M1FA
2
BR285
5
3
OR275
K6
MAG
TAPS
FAN
1-2 = 208VAC
1-3 = 240VAC
K3
RELAY ASSY
PINOUT
K2
K1