TROUBLESHOOTING

Symptom
Possible Cause
No Heat/No Cool/No Fan
1. Blown fuse or tripped circuit breaker.
(common problems)
2. Furnace power switch to OFF.
3. Furnace blower compartment door or
panel loose or not properly installed.
No Heat
1. Pilot light not lit.
2. System Switch not set to HEAT.
3. Loose connection to thermostat or
system.
4. Furnace Lock-Out Condition. Heat may
also be intermittent.
5. Heating system requires service or
thermostat requires replacement.
No Cool
1. System Switch not set to COOL.
2. Loose connection to thermostat or
system.
3. Cooling system requires service or
thermostat requires replacement.
Heat, Cool or Fan Runs
1. Possible short in wiring.
Constantly
2. Possible short in thermostat.
3. Possible short in heat/cool/fan system.
4. Fan Switch set to Fan On.
Furnace Cycles Too Fast
The location of the thermostat and/or
or Too Slow
the size of the Heating System may be
(narrow or wide
infl uencing the cycle rate.
temperature swing)
Cooling Cycles Too Fast
The location of the thermostat and/or the
or Too Slow (narrow or
size of the Cooling System can infl uence
wide temperature swing)
the cycle rate.
Thermostat Setting and
Thermostat thermometer setting requires
Thermostat Thermometer
adjustment.
Disagree
Blank Display and/or
1. Thermostat loss of power.
Keypad Not Responding
2. Voltage spike or static discharge.

LIMITED WARRANTY

Your Research Products Corporation Aprilaire
Research Products Corporation's exclusive obligation under this warranty shall be to supply, without charge, a replacement for any thermostat which is found to be defective within a two (2) year period and which
is returned, together with the date of installation, no later than thirty (30) days after said two (2) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY
YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID TWO YEAR PERIOD. RESEARCH PRODUCTS CORPORATION'S
LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE
ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR
CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitations may not apply to you.
This warranty gives you specifi c legal rights and you my also have other rights which vary from state to state.

WARRANTY REGISTRATION

Please... Take a few minutes to visit us online at www.aprilaire.com to register your Aprilaire product. If you do not have online access,
please mail a postcard with your name, address, phone number, product or model purchased, date of purchase and dealer name to:
YOUR WARRANTY REGISTRATION INFORMATION WILL NOT BE SOLD OR SHARED OUTSIDE OF THIS COMPANY.
61000472 6.06
P.O. BOX 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairecontractor.com
B2204147B
6
®
Thermostat unit is expressly warranted for two (2) years from date of installation to be free from defects in materials and workmanship.
Research Products Corporation, P.O. BOX 1828, Madison, WI 53701
RESEARCH PRODUCTS CORPORATION
Corrective Action
1. Replace fuse or reset breaker.
2. Turn switch to ON.
3. Replace door panel in proper position to engage safety interlock or door switch.
1. Re-light pilot.
2. Set System Switch to HEAT and raise setpoint above room temperature.
3. Verify thermostat and system wires are securely attached.
4. Many furnaces have safety devices that shut down when a lock-out condition occurs. If the heat
works intermittently, contact the furnace manufacturer or local service person for assistance.
5. Diagnostic: Set System Switch to HEAT and raise the setpoint above room temperature.
Within a few seconds, the thermostat should make a soft click sound. This sound usually
indicates the thermostat is operating properly. If the thermostat does not click on,
contact your heating and cooling service person or place of purchase for a replacement.
If the thermostat clicks, contact the furnace manufacturer or a service person to verify
the heating is operating correctly.
1. Set System Switch to COOL and lower setpoint below room temperature.
2. Verify thermostat and system wires are securely attached.
3. Same procedure as diagnostic for No Heat condition except set the thermostat to COOL
and lower the setpoint below the room temperature. There may be up to a fi ve minute
delay before the thermostat clicks in Cooling.
1. – 4. Check each wire connection to verify they are not shorted or touching together. No bare
wire should stick out from under terminal screws. If the condition persists, the manufacturer
of your system or service person can instruct you on how to test the Heat/Cool system for
correct operation. If the system operates correctly, replace the thermostat.
Digital thermostats normally provide precise temperature control and may cycle faster
than some older mechanical models. A faster cycle rate means the unit turns on and off
more frequently but runs for a shorter time so there is no increase in energy use. If you
would like to increase the cycle time, go to menu mode as mentioned in the instructions
for Hydronic Heating Systems. It is not possible to shorten the cycle time. If an acceptable
cycle rate is not achieved as received or by changing cycle time from FAST to SLOW on the
menu mode, contact a local service person for additional suggestions.
The cycle rate for cooling is fi xed and cannot be adjusted. Contact a local service person
for suggestions.
The thermometer can be adjusted +/- 4 degrees. See Select Temperature Display
Adjustment (#5 in the Confi guration Menu section).
1. Check possible blown fuse or tripped breaker.
2. Turn system power off. Wait for 5 minutes and turn the power on.