Nxc-Irs4 4-Port Ir/S Control Card; Specifications - AMX NetLinx NXM Series Operation/Reference Manual

Cardframe, control cards, and netmodules
Hide thumbs Also See for NetLinx NXM Series:
Table of Contents

Advertisement

NXC-IRS4 4-Port IR/S Control Card

The NXC-IRS4 4-Port IR/S Control Card (FG2023) provides four IR/Serial input control ports with LED
status feedback. Each port in the NXC-IRS4 stores programmed commands for IR- or serial-controlled
devices. FIG. 5 shows the IRS4 card.
FIG. 5
NXC-IRS4 4-Port IR/Serial Control card

Specifications

NXC-IRS4 Specifications
Power Requirements
Power
Operation:
IR 1-4
Input 1-4
Memory
IR Frequency range
Status LEDs:
(2 LEDs per channel)
LEDs light to indicate
ON status
Connections/wiring
NetLinx Cardframe, Control Cards, and NetModules
110 mA @ 12 VDC
+12 VDC power for sensors
4 IR/Serial control ports
4 input ports for closure or 0-5 VDC sensing, 200 mA
32K of IR memory shared between four ports.
Support of high-frequency carriers up to 1.14 MHz.
Red LED shows IR transmission activity/Yellow LED shows input status activity:
LED 1: Channel 1 Input (yellow)
LED 2: Channel 1 IR Out (red)
LED 3: Channel 2 Input (yellow)
LED 4: Channel 2 IR Out (red)
LED 5: Channel 3 Input (yellow)
LED 6: Channel 3 IR Out (red)
LED 7: Channel 4 Input (yellow)
LED 8: Channel 4 IR Out (red)
• Two 2-pin 3.5 mm captive-screw terminals
• Two CC-NIRC IR Emitters
NXC-IRS4 4-Port IR/S Control Card
19