Smoke Mode Fuel Feed Rate
In smoke mode, increasing the "P" setting decreases the fuel feed rate, lowering the grill temperature. Start at setting
"P2", adjust the "P" setting manually for the desiredtemperature and/or smoke output.

ERROR MODES AND MESSAGES

Inadvertent Start Error (ErP)
If the cook control switch is set to Smoke or to a temperature setting at the time the grill is plugged in, the control will
display "ErP" indicating an inadvertent start error. The standard ignition sequence is halted.
This feature prevents an inadvertent start. For example, if the grill is stored in the garage, the grill will not ignite if
plugged in inadvertently.
To clear the error, set the cook control switch to the off position
High Temperature Limit Error (ErH)
If the grill temperature exceeds 615 degrees, the control limit error (ErH) displays "ErH" indicating a high
temperature limit error.
The fuel feed auger is turned off , the igniter is turned off , and the draft fan is turned off .
To clear the error, set the cook control switch to the off position. If the error will not clear, your temperature
detector is not functioning normally See "Display is Flashing 'ErH'" in the "Troubleshooting" section.
Flashing In cook mode, the displayed temperature fl ashes if the grill temperature is below 150 degrees.
This is not an error condition and does not aff ect the operation of the grill. The fl ashing display is designed to alert the
operator that there is some risk of the fi re going out.
In smoke mode, the displayed temperature fl ashes if the grill temperature is below 110 degrees.
This is not an error condition and does not aff ect the operation of the grill. The fl ashing display is designed to alert the
operator that there is some risk of the fi re going out.
Flashing Dots
The igniter is on.
This is not an error condition and does not aff ect the operation of the grill. The fl ashing dots are designed to alert the
operator that the igniter is on.