*Note 3 Water Flow Servo Positioning
Servo Position
08
Inlet water temperature
(PCB recognition value)
(Example 25 = 25 C)
09
Hot water fan current flow value
(Example 6 x 10 = 60 mA)
10
Bath fill amount (this counts the litres during bath
fill operation).
11
Heat exchanger exit thermistor temperature
Example 55 = 55 C)
12
Bypass servo present recognition positioning
(Example

To return to normal operation

Press the ON/OFF button again while holding down the Water Temperature "DOWN" (Cooler)
button.
Error History

To Display Error Memory (History)

(This feature will show the last 10 faults in sequence)
1.
Turn off at the ON/OFF button. (This can be done during
operation)
2.
Press the ON/OFF button while holding the Water Temperature
"UP" (Hotter) button.
The Sequence will be shown in the Water Temperature display.
Error Code will be shown in the Clock display. (See service
Manual for error codes).
Where there are less than a total of 9 errors, "FFF" or " - - " will
be displayed in the Clock display.
To return to normal operation.
Press the ON/OFF button again while holding the Water Temperature "UP" (Hotter) button.
This feature will automatically shut down after 3 minutes.
Infinity REU-V2632FFU / HD200I REU-V2632FFUC
Infinity 26i and HD50i
Open
Display
"1"
°
°
0 = Closed
160 = Half open
320 = Open
Centre
"0"
°
C
10 mA
Litres
°
C
Degrees
- 24 -
Closed
"2"
0~999
0~999
0~999
0~999
0~320
Issue 1 - 8/09/03 ©Rinnai