5. Instructions For Use Cont.
Warnings: Do not attempt to start the boiler unless all cleanout doors are secured
and sealed. Do not attempt to light the burner by hand.
1 Check that the cocks connected to the
gas inlet pipe and to the supply cold wa-
ter inlet pipe (see section 3.3 for pipes)
are open.
2 Power the boiler electrically by setting the
power switch foreseen in the installation.
The LCD display shows the sequence
(figure 5.2).
3 If the appliance will not operate, follow
the extinguishing instructions on page 14
and call your service technician or gas
supplier.
The Function switch and Central heating temperature adjustment (7) knob must be in OFF
position.
Press the boiler reset/setting button (6) and simultaneously rotate the domestic hot water tem-
perature control (8) knob to:
• position 1 for °C unit (figure 5.3)
• position 7 for °F unit (figure 5.4)
By releasing the boiler reset/setting button (6), the display indicates the temperature in the
chosen unit.
8
Figure 5.3
RIVA ADVANCE USER MANUAL

5.3 Lighting/Operating Instructions:

5.4 Temperature unit setting (°C or °F):
7
6
Figure 5.2
8
7
6
Figure 5.4