Chapter 5 Input/Output Interfaces
Status Register, I/O Port 379h, Read Only
This register contains the current printer status. Reading this register clears the interrupt condition
of the parallel port.
Bit
Function
7
Printer Busy (if 0)
6
Printer Acknowledgment Of Data Byte (if 0)
5
Printer Out Of Paper (if 1)
4
Printer Selected/Online (if 1)
3
Printer Error (if 0)
2
Reserved
1
EPP Interrupt Occurred (if set while in EPP mode)
0
EPP Timeout Occurred (if set while in EPP mode)
Control Register, I/O Port 37Ah
This register provides the printer control functions.
Bit
Function
7,6
Reserved
5
Direction Control for PS/2 and ECP Modes:
0 = Forward. Drivers enabled. Port writes to peripheral (default)
1 = Backward. Tristates drivers and data is read from peripheral
4
Acknowledge Interrupt Enable
0 = Disable ACK interrupt
1 = Enable interrupt on rising edge of ACK
3
Printer Select (if 0)
2
Printer Initialize (if 1)
1
Printer Auto Line Feed (if 0)
0
Printer Strobe (if 0)
Address Register, I/O Port 37Bh (EPP Mode Only)
This register is used for selecting the EPP register to be accessed.
Data Port Registers 0-3, I/O Ports 37C-Fh (EPP Mode Only)
These registers are used for reading/writing data. Port 0 is used for all transfers. Ports 1-3 are used
for transferring the additional bytes of 16- or 32-bit transfers through port 0.
FIFO Register, I/O Port 7F8h (ECP Mode Only)
While in ECP/forward mode, this location is used for filling the 16-byte FIFO with data bytes.
Reads have no effect (except when used in Test mode). While in ECP/backward mode, reads
yield data bytes from the FIFO.