Ready To Arm
Prod. Id. : XXXX Sw. Rev.: XX.XX
CRC Number: XXXX
RF Version Number: XXXXXX
WiFi Ver: X.X.X
Walk Test
Dialer Test
Walk Test
FAULT ZONES. Open each protected door and window in turn and listen for three beeps from the control,
followed by the zone's Voice Descriptor, if it is programmed. Identification of each faulted protection point
should appear on the display. The display will clear when the door or window is closed.
Walk in front of any interior motion detectors (if used) and listen for three beeps and/or voice descriptors, if
programmed. The identification of the detector should appear on the display when it is activated, and its voice
descriptor will be announced (if programmed). The display will clear when no motion is detected. Note that if
wireless motion detectors are used, in order to conserve battery life, there is a 3-minute delay between
activations.
To test all smoke detectors, follow the manufacturer's instructions. The identification of each detector should
appear on the display when each is activated.
If a problem is experienced with any protection point (no confirming sounds, no display), notify your service
company.
When all protection points have been checked and are intact (closed), there should be no zone identification
numbers displayed on the touch screen.
Test Communications
Depending upon the Communication device that installed in your system the following options may be
displayed. Select the desired option to send a test alarm to the Central Station.
Test Ethernet
If the test is successful, the System displays: Service OK
Send Any
Send GSM Message
Send Ethernet Message
If the test is successful, the System displays: Test Message Sent
If the test is not successful, the System displays: Test Message Failed – Not Registered!
Exiting Test Mode
When testing is completed, exit the Walk Test, Dialer Test or Comm. Test mode by selecting the Home key and
entering the Master User Code (if required).
NOTE: If the Walk Test mode is inadvertently left active, it automatically turns off after 4 hours. The Dialer Test mode will remain
active until exited via an Off sequence.
LYNX Touch Exit/Entry Delay Times
The LYNX Touch will send an event code to the Central Station after entering and after exiting from Test
mode.
Testing the System (to be conducted weekly)
4. Select the "Walk Test", "Dialer Test", "Comm. Test" or
5. "Walk Test..." is displayed on the system status bar and the
Comm. Test
Reboot
6. If the dialer test is unsuccessful the system will display a
Back
5200-100-087-V0
7. The system will advance to the Communications Test Screen.
8. The system will reboot itself.
9. After the reboot sequence is completed, conduct a Walk Test
"Reboot" icon. If Walk Test is selected proceed to Step 5. If
Dialer Test is selected proceed to Step 6. If Comm. Test is
selected proceed to Step 7. If Reboot is selected proceed to
Step 8.
control sounds a single beep every 30 seconds. Fault each
zone as described below.
Reporter Failure message. Contact your security service
provider.
Refer to the Communications Test paragraph.
to verify that all transmitters are operational in the system.