Download Print this page

Python 1600XP Installation Manual page 52

Directed electronics
Hide thumbs Also See for 1600XP:

Advertisement

t t a a b b l l e e o o f f z z o o n n e e s s
When using the Diagnostic functions, use the Table of Zones to see which input has triggered the system. It is
also helpful in deciding which input to use when connecting optional sensors and switches.
Z Z O O N N E E N N O O . .
T T R R I I G G G G E E R R T T Y Y P P E E
1
Trunk Input
2
Multiplexed Shock Sensor Input Mux BLUE wire.
3
Door Trigger
4
Multiplexed Shock Sensor Input Mux GREEN wire
5
Ignition
6
Hood Brake Trigger
N N O O T T E E : The Warn Away® response does not report on the LED.
s s h h u u t t d d o o w w n n d d i i a a g g n n o o s s t t i i c c s s
t t o o p p e e r r f f o o r r m m s s h h u u t t d d o o w w n n d d i i a a g g n n o o s s t t i i c c s s
1. With the ignition OFF, press and H H O O L L D D the Valet/Program button.
2. Turn the ignition ON and then back OFF while H H O O L L D D I I N N G G the Valet/Program button.
3. Release the Valet/Program button.
4. Press and release the Valet/Program button. The LED will report the last shutdown for one minute or until
the ignition is turned on.
L L E E D D F F L L A A S S H H E E S S
One
Two
Three
Four
Six
Seven
Eight
5 5 2 2
I I N N P P U U T T D D E E S S C C R R I I P P T T I I O O N N
BLUE (H1/7)
GREEN (H1/8) and VIOLET (H1/6).
Yellow ribbon harness wire
GRAY on the 6-pin shutdown harness.
S S H H U U T T D D O O W W N N M M O O D D E E
Timed out
Over-rev shutdown
Low or no RPM
Transmitter shutdown (or optional push-button)
(-) Shutdown (H3/4 GRAY) or (+) Shutdown (H3/3 BROWN)
(-) Neutral safety shutdown (H3/1 BLACK/WHITE)
Wait-to-start timed out
© 2005 Directed Electronics—all rights reserved

Advertisement

loading