Heat Pump Heating - Carrier Infinity SYSTXCCITW01 Installation Instructions Manual

Infinity touch control
Hide thumbs Also See for Infinity SYSTXCCITW01:
Table of Contents

Advertisement

display will change to show the AC operating status. After the selections are made,
touch START.
NOTE: Airflows during Checkout modes are fixed to the EFFICIENCY setting
and are independent of other airflow settings. To view airflows for normal air
conditioning cooling mode, exit the CHECKOUT screen and apply a heating
demand to the system.
Low Cool Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
High Cool Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
6.4.5.

Heat Pump Heating

The heat pump heating mode can be exercised with this menu option. With a
2- - stage heat pump, a Low Heat and a High Heat Run Time are independently
selectable to exercise.
For variable speed heat pumps, you can select the speed at which the heat pump
will exercise.
After the selections are made, touch START.
NOTE: Airflows during Checkout modes are fixed to the EFFICIENCY setting
and are independent of other airflow settings. To view airflows for normal air
conditioning cooling mode, exit the CHECKOUT screen and apply a heating
demand to the system.
Low Heat Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
High Heat Run Time: Selectable from 0 to 120 minutes
S
Default = 5 minutes
d
Speed (variable speed heat pump only): Selectable from lowest available to
S
46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ystxccitn01Infinity systxccitn01Infinity systxccitn01

Table of Contents