IBM 8260 Installation Instructions Manual page 22

8260 nways multiprotocol switching hub
Hide thumbs Also See for 8260:
Table of Contents

Advertisement

Installation Instructions
--- VIRTUAL PATH CHANNELS SETTING (VPCS) : --------------------------------
For each LOGICAL LINK in v2.x.x (if VPI was not equal to 0) you must
define a VPC link in v3.1.0 :
1. To set your new VPC_LINKS, YOU NEED THE V2.X.X PARAMETERS YOU
HAVE WRITTEN DOWN IN STEP 6.
example for old CLUSTER 2 HUBc (figure2), now PEER GROUP 2,HUB c:
The VPI on the LOGICAL LINK 4.1 was 3.
Use VPI 3 to set up the new VPC_LINK on PORT 4.1.
HUBc>SET VPC_LINK 4.1 3 ENABLE IISP NETWORK
BANDWIDTH:85000
---REACHABLE ADDRESS SETTING : -------------------------------------------
After having completed the swap, you lose your STATIC ROUTES and LOGICAL LINKS
o Define the reachable address over the IISP link with your old static
route and your old VPI.
example to set up reachability to PEER GROUP 1 HUBb (figure3):
HUBc>SET REACHABLE_ADDRESS
4.1 96 39.99.99.99.99.99.99.00.00.77.77.01 VPI:3
example to set up reachability to PEER GROUP 3 HUBd (figure3):
HUBc>SET REACHABLE_ADDRESS
5.1 96 39.99.99.99.99.99.99.00.00.88.88.03
o Check that your reachable address is active (Y) with the command:
HUBc>SHOW REACHABLE_ADDRESS 5.1
HUBc>SHOW REACHABLE_ADDRESS 4.1
PN : 26L0227
EC : F34705
June 17 1998
Copyright IBM Corp. 1998
Page 22